Rectify Faults - Siemens SITRANS LG270 Operating Instructions Manual

Profibus pa rod and cable probe
Table of Contents

Advertisement

Code
Cause
Text message
S602
Compensation echo superimposed
by medium
Level within the
search range,
compensation
echo
S603
Operating voltage below specified
range
Impermissible
operating voltage
Tab. 8: Error codes and text messages, information on causes as well as corrective measures
Maintenance
Code
Cause
Text message
M500
The data could not be restored dur-
ing the reset to delivery status
Error in the deliv-
ery status
M501
Index markers are not continuous-
ly rising, for example illogical value
Error in the
pairs
non-active line-
arisation table
M504
Hardware defect
Error at a device
interface
M505
Sensor does not detect an echo dur-
ing operation
no measured val-
ue available
Process component or probe con-
taminated or defective
M506
Error during setup
Installation/Set-
up error
M507
Error during setup
Error in the in-
Error when carrying out a reset
strument settings
False signal suppression faulty
Tab. 9: Error codes and text messages, information on causes as well as corrective measures
Reaction when malfunc-
tion occurs
Fault rectification
60
Rectification
100 % adjustment: Increase value
Check electrical connection
If necessary, increase operating
voltage
Rectification
Repeat reset
Load XML file with sensor data into
the sensor
Check linearisation table
Delete table/Create new
Exchanging the electronics
Send instrument for repair
Check and correct mounting and/or
parameter adjustment
Clean or exchange process compo-
nent or probe
Check and correct mounting and/or
parameter adjustment
Check probe length
Carry out reset and repeat setup
9.4

Rectify faults

The operator of the system is responsible for taking suitable meas-
ures to rectify faults.
The first measures are:
Evaluation of fault messages
Checking the output signal
Treatment of measurement errors
SITRANS LG270 - Operating Instructions
TB
Diagnostics
Bit 25
Bit 26
TB
Diagnostics
Bit 15
Bit 16
Bit 19
Bit 20
Bit 20
Bit 21
Bit 22
PBD-51041506

Advertisement

Table of Contents
loading