7

INSTALLATION

7.1
Wall mount mixers
A7216AA A7221AA A7227AA
A7697AA
Ø15mm copper supply pipes should be run within the wall cavity.
Hot supply pipe should be on the left hand side and the cold on the right.
Ensure that the hot and cold pipes are positioned 150mm apart and are level.
Use the template provided to obtain the correct spacing.
50
We recommend leaving 50mm of pipe protruding at this stage.
Pipework should be supported in the cavity
BEFORE CONNECTION, FLUSH WATER
THROUGH PIPEWORK TO REMOVE
ALL DEBRIS ETC. WHICH COULD DAM-
AGE THE VALVE MECHANISM
1
13
IMPORTANT
Pair of wall brackets
with connectors &
escutcheons
Template x1