Cadiz Installation Guide - Surface Profiles – v2022
Insert the 10 mm spacer into the underframe channel and use it to align the wall profile. Push
7
the profile down as far as it will go and, using a spirit level to ensure that it is perfectly vertical,
mark the screw hole positions on the wall. Remove the profile.
Drill 6 mm holes where marked and insert wall plugs.
The Majestic Shower Company Limited
17 Flitch Industrial Estate, Chelmsford Road, Dunmow, CM6 1XJ
Reposition the wall profile and insert the top and bottom screws to hold it in place.
8
Remove the 10mm spacer and insert a rubber strip into the underframe channel
where the Return panel will sit.
Telephone +44 (0) 8448 001 500
Facsimile +44 (0) 1279 635 074 info@majesticshowers.com www.majesticshowers.com
7
Return
Panel