Specification; Installation Conditions - Valor Black Beauty Unigas II Installer's Manual

Room sealed radiant / convector gas fire
Table of Contents

Advertisement

1.

SPECIFICATION

The overall dimensions are shown in figure 1.
Fig. 1 Overall dimensions
Gross Weight:
Main Burner:
Flame Effect Burner:
Gas Connection:
Gross Gas Consumption: 4.9kW at maximum position.
Maximum output:
Injectors:-
Main Burner: Bray Cat. 960 Size 240.
Flame Effect Burner: Bray Cat. 960 Size 130
No component on this appliance is manufactured from asbestos or asbestos related products.
The appliance data label is at the left side of the rear case and is visible after removing the case front. In addition, for
customers reference, there is a label giving the appliance serial number on the outside of the case at the bottom right side.
2.

INSTALLATION CONDITIONS

This product uses fuel effect pieces, burner compartment walls and gaskets containing Refractory Ceramic Fibres (RCF), which
are man-made vitreous silicate fibres. Excessive exposure to these materials may cause temporary irritation to eyes, skin and
respiratory tract. Consequently, it makes sense to take care when handling these articles to ensure that the release of dust is kept to
a minimum. To ensure that the release of fibres from these RCF articles is kept to a minimum, during installation and servicing we
recommend that you use a HEPA filtered vacuum to remove any dust and soot accumulated in and around the fire before and after
working on the fire. When replacing these articles we recommend that the replaced items are not broken up, but are sealed within
a heavy duty polythene bag, clearly labelled as RCF waste. This is not classified as "hazardous waste" and may be disposed of at
a tipping site licensed for the disposal of industrial waste. Protective clothing is not required when handling these articles, but we
recommend you follow the normal hygiene rules of not smoking, eating or drinking in the work area and always wash your hands
before eating or drinking.
2.1
Walls:-
Minimum 102mm (4in.) thick
Maximum 660mm (26in.) thick.
Suitable for use with combustible walls provided that there is no combustible material or combustible cladding in the area
indicated on the wall fixing template.
Please note that soft wall coverings (e.g. embossed vinyls etc.) are easily affected by heat. They may therefore, scorch or become discoloured
when close to a heating appliance. Please bear this in mind when installing.
2.2
Where installation is into a timber framed house, this should be in accordance with Paragraphs 5.2, 5.3, 5.4, 5.5,
5.6, and 6.1 of British Gas publication 'Dm2 Guide For Gas Installations In Timber-Framed Housing'.
For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - info@mytub.co.uk 0844 556 1818
26.2kg
Simplex aerated
Simplex aerated.
RP 1/4 (1/4in. B.S.P) Female.
3.54kW
Pressure Setting (Cold): 18.2 + 0.75mbar
Aeration Adjustment:
None required.
Control Tap:
Variable position fitted with
flame supervision device and integral piezo igniter.
Pilot Unit:
Right side of firebox.
Combined Pilot jet thermocouple sensor and electrode.