Servicing; Outer Case Removal; Window Unit Removal; Ceramic Fuels Removal - Valor Black Beauty Unigas II Installer's Manual

Room sealed radiant / convector gas fire
Table of Contents

Advertisement

15.

SERVICING

Turn off the gas and make sure that the appliance is cool before commencing any servicing.
Always test for gas soundness after refitting the appliance.
15.1
To Remove Outer Case.
15.1.1
Remove the knurled screws at the case sides (see fig.1).
15.1.2
Pull the bottom of the case forwards and then lift the case clear.
15.2
To Remove Window Unit
15.2.1
Remove the outer case as 15.1 above.
15.2.2
Remove the window unit by detaching the 12 wing nuts securing the frame (see fig. 3) and pulling forward.
15.3
To Remove The Ceramic Fuel Items
15.3.1
Remove the outer case as 15.1 above.
15.3.2
Remove the window unit as 15.2 above
15.3.3
Remove the coals carefully
15.3.4
Lift out the coal bed
15.3.5
Replace the items as described in the installation instructions.
15.4
To Remove Burner(s)
15.4.1
Remove the outer case as 15.1 above
15.4.2
Remove the window unit as 15.2 above.
15.4.3
Remove the ceramic items as 15.3 above.
15.4.4
Remove the burner front cover by unscrewing 14 screws.
15.4.5
Remove the front ceramic support bar by unscrewing 1 screw each side.
15.4.6
Remove the burner(s) by unscrewing one screw at the left side and lifting clear.
15.4.7
The main and decorative flame burners are of different lengths. They cannot be fitted in the wrong positions.
15.5
To Remove Injectors(s)
15.5.1
Remove the outer case as 15.1 above.
15.5.2
Release the pipe compression fitting(s) to the injector(s).
15.5.3
Loosen the pipe compression fitting(s) to the tap and move the pipe(s) clear.
15.5.4
Remove the injector(s) and carrier(s) from the firebox side.
15.5.5
Remove the injector(s) from the carrier(s)
15.6
To Remove Thermocouple
15.6.1
Remove the outer case as 15.1 above.
15.6.2
Disconnect the thermocouple at the gas tap end.
15.6.3
Undo the nut securing the thermocouple to the pilot unit bracket outside the firebox side. Withdraw the
thermocouple.
15.7
To Remove Electrode Pin
15.7.1
Remove the outer case as 15.1 above.
15.7.2
Disconnect the electrode lead at the pilot unit end.
15.7.3
To gain access to the electrode nut, disconnect the thermocouple at the pilot unit end as 15.6.3 above.
15.7.4
Undo the nut securing the electrode ceramic and pin to the pilot unit bracket.
15.8
To Remove Pilot Pipe & Jet
15.8.1
Remove the outer case as 15.1 above
15.8.2
Unless the appliance is sufficiently high above the floor to allow access from underneath, remove the
thermocouple and electrode pin from the pilot bracket as 15.7.3 and 15.7.4 above.
15.8.3
Release the pilot pipe from the gas tap.
15.8.4
Unscrew the pilot pipe from the pilot bracket.
15.8.5
Carefully withdraw the pilot pipe from the pilot bracket - when withdrawing, the pilot jet will be pulled out.
15.8.6
When replacing, make sure that the pilot jet is hooked over the seating at the end of the pipe.
For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - info@mytub.co.uk 0844 556 1818