Technical Specification; Pack Contents - Valor COSYFLAME BR623 Installer's Manual

Hide thumbs Also See for COSYFLAME BR623:
Table of Contents

Advertisement

An extractor fan may only be used in the same room as this appliance, or in any area from which ventilation for the appliance is
taken, if it does not affect the safe performance of the appliance. Note the spillage test requirements detailed further on in this
manual. If the fan is likely to affect the appliance, the appliance must not be installed unless the fan is permanently disconnected.
The appliance is fitted with an A.S.D (Atmosphere sensing device). If the appliance closes down after a period of operation for
no apparent reason, the consumer should be informed to stop using the appliance until the installation and appliance have been
thoroughly checked. The A.S.D will shut the appliance down if an unacceptable amount of harmful products of combustion
accumulate. Under no circumstances should the A.S.D be altered or bypassed in any way. Only a genuine Valor supplied
replacement part should be fitted. The individual A.S.D components are not replaceable.
Note that soft wall coverings (e.g. embossed vinyl, etc.) are easily affected by heat. They may scorch or become discoloured when
close to a heating appliance. Please bear this in mind when installing.
Propane gas appliances must not be installed in a room, which is built entirely below ground level (See BS 5871 Pt2).
Fire surround height:
Fire surround height:
Appliance depth:
Height of opening required:
Width of opening required:
Inlet Pressure
Input - Max. (Gross)
Input - Min. (Gross)
Output - Max.
Output - Min
Burner Test Pressure (Cold)
Gas Connection
Burner Injector
Pilot & Atmosphere Sensing
Device
Ignition
Aeration
*
When converted using Kit 591149
Clearance to combustible side panels:
The minimum height from the top surface of the hearth to the underside of any shelf made from wood or other combustible
materials is as follows: -
• For a shelf up to 150mm deep
Minimum height = 750mm.
• For a shelf deeper than 150mm
Minimum height = 750mm + 12.5mm for every 25mm depth over 150mm.
1 Hotbox and Burner assembly
1 Firefront Pack
1 Ceramics Pack
3 Self-Adhesive Foam seals
2 Tension Cables
2 Cable Adjusters

TECHNICAL SPECIFICATION

600mm
470mm
115mm
535mm min.
575mm max.
335mm min.
435mm max.
Gas
Natural (G20)
20mbar
6.0kW (20,500Btu/h)
2.2kW (7500Btu/h)
3.5kW (11,900Btu/h)
1.1kW (3750Btu/h)
17.0±0.75mbar
(6.8±0.3in w.g.)
8mm pipe
Bray Cat. 18 Size 360
SIT Ref. OP9030
Piezo Electric. Integral with
Gas Tap
Non-adjustable
100mm

PACK CONTENTS

Propane (G31)*
37mbar
6.1kW (20,800Btu/h)
3.6kW (12280Btu/h)
3.6kW (12,280Btu/h)
1.8kW (6140Btu/h)
35.6±0.75mbar
(14.3±0.3in w.g.)
8mm pipe
Bray Cat. 18 Size 170
SIT Ref. OPLPG9222
Piezo Electric. Integral with
Gas Tap
Non-adjustable
2 Eyescrews
2 Fibre Plugs
1 Strip of Floor Sealing Tape
1 Literature Pack
1 Nut and Olive for 8mm Inlet Pipe
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Grampian br427

Table of Contents