CAUTION IN SERVICING

Updating this unit

• When you replace the IC113, you need software updates. See "After replacing IC113".
• When you replace the WLAN MODULE, you need software updates. And MAC Address seal replacement is required.
See "After replacing WLAN MODULE".

Initializing this unit (Initialization for the factory)

This unit initialization should be performed when the μcom, peripheral parts of μcom, and WLAN MODULE are replaced.
d
1. Press the power operation button " X " to turn off the power, and remove the AC plug from the socket.
2. While holding down buttons "SOURCE" and "CURSOR d " simultaneously, insert the AC plug into the wall outlet to
turn on the power. (Factory Reset)
3. Press the power operation button to place this unit on standby.
4. While holding down buttons "SOURCE" and "CURSOR f " simultaneously, press the power button to turn on the
power. (Initialized)
5. Wait for more than 90 seconds after "Initialized" is displayed and then turn the power off.
(During this time, start and initialize the network devices.)
NOTE: • If step 5 fails, start over from step 1.
• All user settings will be lost and the factory setting will be recovered after the set is initialized.
So make sure to note down your setting beforehand for restoring after the initialization.
Cursor buttons (
)
Power operation button (X)
Input source select button (SOURCE)
Power indicator
.
SOURCE
5V/1A