Digital output (DOUT)

Function of digital output 0*
P0731 =...
Defines source of digital output 0.
Invert digital output
P0748 = 0
Allows the signals to be output to be inverted.
Status of DOUT at logically active signal (0 = Open; 1 = Closed)
Frequent settings:
0
Not Active
1
Active
2
Drive ready
3
Drive ready to run
4
Drive running
5
Drive fault active
6
OFF2 active
7
OFF3 active
8
Switch on inhibit active
9
Drive warning active
10
Deviation between f
11
PZD control (P0700=5)
12
Act. Freq
13
Warning: Motor current limit
14
Motor holding brake active*
15
Motor overload
*Note: Motor holding brake active means the brake is open.
6.2.5

Selection of frequency setpoint

Selection of frequency setpoint
P1000 =...
0
No main setpoint
1
MOP setpoint
2
Analog setpoint
3
Fixed frequency
5
USS
SINAMICS G110
Operating Instructions (Compact)
and f
< 3 Hz
set
act
P1082 (f
)
max
DOUT channel
Function of digital output 0
0 ... 22
Invert digital outputs
P0731 (5)
0 ... 1
P0748 (0)
0
23
2 / 5
Active
-
-
High
High
High
High
Low
Low
High
High
High
High
High
High
High
High
CO/BO: State of digital outputs
r0747
r0747
.0
0
-1
1
2
1
P1000
G110 AIN G110 USS
0
X
1
X
2
X
3
X
5
6 Commissioning
5
0
Status
0 (always)
1 (always)
1
1
1
0
0
0
1
1
1
1
1
0
1
0
DOUT+
24 V DC 50 mA
DOUT-
Settings
X
X
see 6.2.7
see 6.2.6
X
see 6.2.8
X
see 6.2.1
19