Daikin FTXTA30AW Service Manual page 92

Optimized heating 4
Table of Contents

Advertisement

ESIE17-19C
|
Part 3. Repair
I
NFORMATION
The expansion valve motor (
the pipe (
2)
to lock the expansion valve motor (
2.
When installing the expansion valve motor (3), lock it on the expansion valve on the CORRECT direction.
1. Pipe retention clip
2. Pipe
Installation with bracket
I
NFORMATION
Replace all tie wraps that were cut during removal.
1.
Proceed in reverse order.
I
NFORMATION
The expansion valve motor (
4
notches (
) of the expansion valve body (
2.
When installing the expansion valve motor (1), lock it on the expansion valve.
Page 92
Optimized Heating 4
3
) is equipped with a pipe retention clip (
3
).
Figure 3-22: Locking the expansion valve motor
3
1
2
Y1S
1
) is equipped with a metal bracket (
5
).
3.3. Unit specific repair procedures
1
). The pipe retention clip (
3. Expansion valve motor
2
3
). Fit the nipples (
) of the metal bracket (
1)
must be placed over
2
) into the
19/08/19
|