5.1. Field setting

5.1.1. Indoor unit
5.1.1.1. How to activate fireplace logic
ARC466A55
5.1.1.2. Only for FTXTA-A
5.1.1.2.1 To control heating mode only
Prerequisite: Stop operation of the unit.
1.
Press
,
and
simultaneously.
2.
Press
.
3.
Select SU.
4.
Press
to confirm.
5.
Press
.
6.
Select 19.
7.
Press
to confirm.
8.
Press
.
9.
Select 1 (0: factory setting, 1: heating only).
10. Press
to confirm.
5.1.1.2.2 To adjust target set temperature in heating operation
I
NFORMATION
When there is a big difference between the indoor room temperature and the set temperature in heating mode, adjust the target set temperature field setting.
Target temperature= remote controller set temperature + 2.5°C.
For example:
Remote controller set temperature= 20°C
Target temperature= 20°C + 2.5°C= 22.5°C
Thermo off temperature= 24.5°C
1.
Press
,
and
simultaneously.
2.
Press
.
3.
Select SU.
4.
Press
to confirm.
5.
Press
.
6.
Select 7.
7.
Press
to confirm.
19/08/19
|
Version 1.1
Optimized Heating 4
For symbol use 'hot wind' without the frame.
How to activate 'fireplace logic':
1. Set unit to heating mode - symbol for heating
2. Set by
button 'fireplace function'
So active 'fireplace logic' on R/C is indicate by:
heating symbol continuously light
fan symbol continuously light
Original button:
st
1
push - streamer activated
nd
2
push - streamer deactivated
New proposal of button:
st
1
push - only streamer activated
nd
2
push - only fireplace logic activated
rd
3
push - streamer and fireplace logic activated
th
4
push - streamer and fireplace deactivated
on display light continuously.
symbol for fan
will start light continuously, it indicates on R/C active fire place logic.