Pro ED Fast Gate Training Manual
4. M
ECHANICAL

4.1 Pneumatic Controls

MANUAL OVERIDE
SOLENOID 24 VAC.
MANUAL MODE ONLY
FILTER REGULATOR
AND WATER TRAY
ICE PNEUMATIC
CYLINDER
(SPRING RETURN)
CO
Regulator
2
• Works with CO
• Preset to 34 psi (± 2 psi)
Pneumatic Solenoid Valve
• When set to the manual mode, 24 VAC is applied to the manual override
solenoid providing an open chute for direct dispense of ice via the red
manual push button.
• When set to the auto/ice portion control mode, 12 DCV is applied to the
auto pneumatic solenoid when depressing one of the ice portion buttons.
The ice gate closes by spring pressure.
5. C
OOLING
High performance cold plate accepts cubed and chunklet™ compressed ice. Never use
flaked ice in this unit!
- 4 -
PNEUMATIC GATE
SOLENOID VALVE
PRESSURE
GAUGE
WATER
DRAIN
ICE GATE
ADJUSTMENT
ADJUSTABLE
only
2
12 VAC PORTION CONTROL
AUTO MODE.
ICE GATE
© 2003 IMI Cornelius Inc.