Pro ED Fast Gate Training Manual
L
ICE CHUTE
INTERLOCK
SWITCH
BEVERAGE
TRANSFORMER
24VAC
1
AGITATOR
RELAY
2
MANUAL ICE
DISPENSE SWITCH
NOTE:THERE ARE ONLY TWO OFF CYCLE AGITATION TIME OPTIONS. IF THE CHUTE REFILL IS SET
FOR SMALL, MEDIUM, OR LARGE THE OFF CYCLE TIME WILL BE 30 MINUTES, THE ON
CYCLE TIME WILL BE (4) SECONDS. X-LARGE CHUTE REFILL SETTING WILL RESULT IN A 60
MINUTE OFF CYCLE AND A (4) SECOND ON CYCLE.
- 20 -
120V
INTERLOCK RELAY
TRANSIENT VOLTAGE
SUPPRESSOR
24VAC
BEV ON/OFF
SWITCH
BEV
BEV
VALVE
VALVE
BEV
BEV
VALVE
VALVE
BEV
BEV
VALVE
VALVE
BEV
BEV
VALVE
VALVE
24VAC
3
CONTROLLER/TOUCH PANEL
4
PNEUMATIC
ICE GATE
SOLENOID VALVE
O/L
AGITATOR MOTOR
HEATER
TRANSIENT VOLTAGE
SUPPRESSOR
BEVERAGE
TRANSFORMER
24VAC
MANUAL OVERIDE
SOLENOID VALVE
MANUAL/AUTO
ICE TOGGLE
SWITCH
PORTION
AGITATOR MOTOR
R
S
START CAPACITOR
N
TOUCH
PANEL
3
2
4
MOTOR
START
RELAY
© 2003 IMI Cornelius Inc.