Drain Tube Inspection

Condensation Inspection

Refrigeration System Inspection

Overall Mechanical Inspection

Auger Bearing Inspection

© 2012-2014,Cornelius Inc. All Rights Reserved
Check the drain tubes for clogs and aged tubing. If tubes are stained or brittle, replace
them with new tubing.
Check for signs of condensation. Clean the area where necessary and replace insu-
lation in the proper locations.
Visually inspect the refrigeration system for signs of wear or leaks. Call service if
repairs are needed.
Check unit for any unusual noise or rattles. Tighten any loose screws if necessary.
Check white upper auger bearings for wear. If bearings are less than 1/16" thickness,
replace the bearing. Refer to Figure 29.