Furuno FELCOM 50 Installation Manual

Inmarsat fleet f55 ship earth station
Hide thumbs Also See for FELCOM 50:

Advertisement

Quick Links

INMARSAT FLEET F55
SHIP EARTH STATION
FELCOM 50
P R I N T E D  I N  J A P A N

Advertisement

Table of Contents
loading

Summary of Contents for Furuno FELCOM 50

  • Page 1 INMARSAT FLEET F55 SHIP EARTH STATION FELCOM 50 P R I N T E D  I N  J A P A N...
  • Page 2 The paper used in this manual is elemental chlorine free. FURUNO Authorized Distributor/Dealer FURUNO Authorized Distributor/Dealer 9-52 Ashihara-cho, 9-52 Ashihara-cho, Nishinomiya 662-8580, JAPAN Nishinomiya 662-8580, JAPAN Telephone : Telephone : 0798-65-2111 0798-65-2111 0798-65-4200 0798-65-4200 FIRST EDITION : FIRST EDITION :MAR.
  • Page 3: Antenna Unit

    www.reelschematic.com www.reelschematic.com SAFETY INSTRUCTIONS WARNING WARNING Do not open the equipment Ground the equipment to unless totally familiar with prevent electrical shock electrical circuits and and mutual interference. service manual. Only qualified personnel Confirm that the power supply voltage ELECTRICAL should work inside the is compatible with the voltage rating SHOCK...
  • Page 4: Table Of Contents

    www.reelschematic.com www.reelschematic.com TABLE OF CONTENTS SYSTEM CONFIGURATION ....................iii EQUIPMENT LISTS .........................iv PLANNING.........................1 Placing the Antenna Unit ......................1 Designing the Antenna Mast....................4 Mounting Dimensions of Units....................6 Communication Unit Connectors..................8 Examples of Installation......................9 Placing Units........................11 Grounding Considerations....................13 Laying Cables ........................14 Telephone Wiring ........................15 INSTALLATION.......................
  • Page 5: System Configuration

    www.reelschematic.com www.reelschematic.com SYSTEM CONFIGURATION Antenna Unit optional supply standard supply SF-150 ISDN Handset N Type SF-870 shipyard supply Antenna cable φ 103154 25m N Type RJ-45 ISDN (RJ-45) RJ-11 RJ-11 RJ-45 Terminal ISDN cable ISDN Adapter QRPM911-3000 (RJ-45) RJ-45 G3 FAX (3 m) QDGY 911912 FAX-2820...
  • Page 6: Equipment Lists

    www.reelschematic.com www.reelschematic.com EQUIPMENT LISTS Standard Supply Name Type Code No. Remarks Antenna Unit SF-150 — w/cable 103154 (25 m) Communication SF-250 — Unit ISDN Handset SF-870 — Terminal Adapter QDGY911912 000-147-698 Installation CP16-03200 000-150-697 Materials* CP16-03210 000-043-445 Accessories FP16-03000 000-043-466 CD-ROM for communication unit *: See lists at the back of this manual.
  • Page 7 www.reelschematic.com www.reelschematic.com Optional supply (con’t) Name Type Code No. Remarks Transformer E-300+cable Transformer 0P16-25 004-446-850 100VAC→220VAC (300VA) For FAX-2820 Analog Telephone DBR104001/888 000-147-693 Terminal Adapter QDGY911912 000-147-698 ISDN Wall Socket 102176 000-147-699 ISDN Handset SF-870 000-043-252 Incoming Indicator KK-893-3977 000-148-478 For analog telephone line Signal Cable S16-4-15...
  • Page 8: Planning

    www.reelschematic.com www.reelschematic.com PLANNING Placing the Antenna Unit General Interfering objects (especially metallic objects such as masts) near the antenna can, in the worst case, prevent reception or transmission. Further, RF radiation from the antenna will affect the human body. Keep these and the following guidelines in mind when selecting a mounting location for the antenna unit.
  • Page 9 www.reelschematic.com www.reelschematic.com Locate away from passengers and crew Radio waves can be harmful to the human body. Since safe distances vary by country and ship construction there is no uniform formula for calculating safe distance. However, below are general guidelines. •...
  • Page 10 www.reelschematic.com www.reelschematic.com Minimum distance from other antennas HF antennas, communication/navigation antennas: The antenna should be at least 5 meters from a HF antenna. VHF, satellite navigation antenna and other communication antennas should be at least 4 meters away. Radar: The antenna should be at least 5 meters away to protect the low noise amplifier in the radar antenna.
  • Page 11: Designing The Antenna Mast

    www.reelschematic.com www.reelschematic.com Designing the Antenna Mast General To facilitate servicing, construct a mast of 1000 mm in height. (See page 5.) The paragraphs which follow provide guidelines for selection and construction of the mast. Guardrail, platform Fit the mast with a guardrail and platform (or steps), for serviceman’s safety. (In most installations the serviceman stands on the platform while checking the radome.
  • Page 12 www.reelschematic.com www.reelschematic.com Mounting pole and mounting base In order to ensure long life for the antenna electronics and mechanics, the antenna must be installed properly on a specially designed pole with suitable flange and rubber gasket. Below are guidelines for installation of the mounting pole and mounting base. •...
  • Page 13: Mounting Dimensions Of Units

    www.reelschematic.com www.reelschematic.com Mounting Dimensions of Units 605 mm M4x24 SOCKET HEAD 630 mm UNBRAKO SCREWS (RADOME TOP FASTENERS) 130 mm 130 mm M8 SOCKETS (4) Bolt length to be entered inside the radome*: - max 20 mm - min 13 mm Max torque 20Nm COAXIAL CONNECTOR...
  • Page 14: Communication

    www.reelschematic.com www.reelschematic.com Communication unit 310 mm 81 mm Notice: Secure free space of at 6.5mm least 15 cm around the CU for adequate cooling, and to allow removal of unit for service. Mass: 3kg ISDN Handset Handset holder/cradle 54mm 22.5 37.5 RJ45 Mass: 0.3 kg...
  • Page 15: Communication Unit Connectors

    www.reelschematic.com www.reelschematic.com Communication Unit Connectors Rear connector panel Battery Terminals 11-32 VDC/110 W ON/OFF 11-32 VDC / 110W SIM CARD NOT IN USE ON/OFF Switch TERM) SIM CARD INSIDE WHEN CHANGING MODEM UNIT REMOVE COVER AND TAKE OUT SIM CARD Do not remove 50 ohm termination SIM Card...
  • Page 16: Examples Of Installation

    www.reelschematic.com www.reelschematic.com Examples of Installation Antenna Cable IS D N H a n d s e t...
  • Page 17 www.reelschematic.com www.reelschematic.com Connection examples 48V DC SYNC ISDN ISDN ALARM RS-232 A RS-232 B 5 4 3 2 1 5 4 3 2 1 9 8 7 6 9 8 7 6 ISDN RS-422 ISDN wall socket Terminal adapter Analog Analog ISDN ISDN...
  • Page 18: Placing Units

    www.reelschematic.com www.reelschematic.com Placing Units Placing the communication unit The communication unit should be placed in a ventilated area. To ensure adequate cooling for the unit, a 10 cm unobstructed space must be maintained above and below the unit. A space of 10 cm above the unit is also required to allow removal of units. Locating the communication unit too close to a compass can affect compass performance.
  • Page 19 www.reelschematic.com www.reelschematic.com Placing the terminal adapter The terminal adapter may be installed almost anywhere. However, install it where vibration is minimal and locate it away from heat sources. Placing the ISDN handset The ISDN handsets may be installed anywhere onboard the vessel. Four separate ISDN ports are available on the communication unit as RJ45 jacks or screw terminal blocks.
  • Page 20: Grounding Considerations

    www.reelschematic.com www.reelschematic.com Placing analog telephones (option) Analog 2-wire telephones can be installed anywhere onboard the vessel. The analog telephone DBAR104001/888 (option) should be installed on a bulkhead. Grounding Considerations A successful installation of a maritime satellite terminal must take into account the noisy environment in which the equipment shall operate.
  • Page 21: Laying Cables

    www.reelschematic.com www.reelschematic.com Mains ground Mains ground is secured to the common grounding point through the external supply. It is therefore important to use the same mains branch for additional equipment connected to the communication unit (Fax, PC w/printer, etc.). See also “Location and grounding of units” on page 18. 48V DC SYNC ISDN...
  • Page 22: Telephone Wiring

    www.reelschematic.com www.reelschematic.com Telephone Wiring connector panel 1 2 3 4 5 6 7 8 ISDN ISDN Handset (terminal) block) DIAL 00+INTL TEL. NO.+ SHIFT BAT ALPHA FUNC ALPHA ENTER SHIFT MORE/ HELP ON/OFF LIST LIST PLAY LIGHT YZÆ DATA ØÁ. ÄÖÜ...
  • Page 23: Installation

    www.reelschematic.com www.reelschematic.com INSTALLATION Open all boxes supplied and check the contents with the enclosed packing list. Inspect units and parts for possible transport damage. Basic Installation Antenna Unit ON/OFF 11-32 VDC / 110W SIM CARD NOT IN USE TERM) Communication Unit SIM CARD INSIDE WHEN CHANGING MODEM UNIT REMOVE COVER...
  • Page 24: Installing The Above Deck Equipment (Ade)

    www.reelschematic.com www.reelschematic.com Installing the Above Deck Equipment (ADE) Unpacking Unpack the antenna unit carefully so as not to damage it. Check the antenna for damage. Mounting procedure 1. Place the antenna unit on the mounting base. 2. Fix the antenna unit to the mounting base with supplied fixing studs, nuts and washers. 3.
  • Page 25: Installing The Below Deck Equipment (Bde)

    www.reelschematic.com www.reelschematic.com Installing the Below Deck Equipment (BDE) Location and grounding of units To next ISDN Wall Socket & ISDN Handset Antenna Cable ISDN Wall Socket ISDN Handset ISDN ALPHA May 01 09:15 4.8 Speech Communication Unit DC power supply Desktop Common ground...
  • Page 26 www.reelschematic.com www.reelschematic.com Installation of cable strain reliever The cable strain reliever is mounted 5-6 cm below the communication unit’s front panel and directly to a bulkhead. The shield of a cable is fastened to a screw on the front panel of the communication unit.
  • Page 27 www.reelschematic.com www.reelschematic.com Example of local or nearby installation The installation includes four ISDN handsets, Group 3 and Group 4 telefaxes, and three PCs. DIAL 00+INTL TEL. NO.+ SHIFT ALPHA 48V DC FUNC ALPHA ENTER MORE/ SHIFT HELP ISDN SYNC ON/OFF LIST ISDN LIST...
  • Page 28 www.reelschematic.com www.reelschematic.com Example of remote installation The installation includes two ISDN handsets connected to the ISDN bus via wallboxes with two 8-pin RJ45 jacks and analog telephone. Digital ISDN telefax (G4) ISDN Handset Handset ISDN Interface Saloon Captain's Cabin ISDN handset Plug the ISDN handset into the ISDN socket located on the connector panel of the CU.
  • Page 29 www.reelschematic.com www.reelschematic.com Handset holder/cradle The handset holder/cradle may be mounted on a desktop or a bulkhead. Desktop mount Bulkhead mount Attach the holder to the bulkhead or desktop with four 4 mm wood screws or self-tapping screws. (Screws should be supplied locally.) Place the handset on the holder as shown.
  • Page 30 www.reelschematic.com www.reelschematic.com Mounting the communication unit Fix the unit to the chosen location with six self-tapping screws. Dia 6.5 Connecting the antenna cable to the communication unit 1. Strip the antenna coaxial cable, leaving sufficient slack for connection to the CU. 2.
  • Page 31 www.reelschematic.com www.reelschematic.com N-P-8DFB connector Attach the connector to the antenna cable as shown below. (Dimensions in millimeters.) Inner Outer Sheath Sheath Shield Armor Cover with heat-shrink tubing and heat. Cut off insulator and core by 10 mm. Twist shield end. Slip on clamp nut, gasket and clamp as shown left.
  • Page 32 www.reelschematic.com www.reelschematic.com N-P-12DSFA connector Attach the connector to the antenna cable as shown below. (Dimensions in millimeters.) Outer Sheath Inner Sheath Shield Remove outer sheath and armor by the Armor dimensions shown left. Expose inner sheath and shield by the dimensions shown left.
  • Page 33: Terminal Adapter Qdgy911912

    www.reelschematic.com www.reelschematic.com Terminal Adapter QDGY911912 ISDN port on FELCOM Terminal Adapter ANALOG ISDN Analog 12 VDC telephone (DTMF) Group 3 telefax Note: The AC/DC Adapter supplied with the Terminal Adapter is designed for connection to 230 VAC. If the ship’s mains is 100 VAC, use a transformer.
  • Page 34: Installing Optional Units

    www.reelschematic.com www.reelschematic.com Installing Optional Units ISDN telephones/equipment ISDN equipment is connected to the ISDN outlets on the CU connector panel, either to terminal blocks or RJ45 jacks. An ISDN bus can be connected to one of the ISDN outlets. Max. extension length: 100 m, min. 0.22 mm Screen ISDN bus: max 100 m Local equipment...
  • Page 35 www.reelschematic.com www.reelschematic.com ISDN connectors ISDN ISDN ISDN connector equipment 48V DC SYNC ISDN ISDN ALARM RS-232 A RS-232 B 5 4 3 2 1 5 4 3 2 1 1 2 3 4 5 6 7 8 9 8 7 6 9 8 7 6 ISDN RS-422...
  • Page 36 www.reelschematic.com www.reelschematic.com ISDN bus termination When longer than 10 meters, the end of the ISDN bus must be terminated by two resistors as shown below. Only one bus/termination per CU. Be aware that only one ISDN cable is permitted to be longer than 10 meters. Alternative termination: ISDN bus end plug 100 ohm...
  • Page 37 www.reelschematic.com www.reelschematic.com RS-232 connector pin assignments 5 4 3 2 1 Mne- CCITT Signal Circuit DIN Dscription number monic circuit source Carrier detect 9 8 7 6 Received Data Tramsmitted Data Signal source DTE means Data terminal ready that the signal goes from the Signal ground PC to FELCOM.
  • Page 38: Facsimile Fax-2820

    www.reelschematic.com www.reelschematic.com Facsimile FAX-2820 Note that the hooks supplied are not used in the installation. Note: When ship’s main is 110/115 VAC, the optional Transformer E-300 is required. 1. Fix the mounting plate to the mounting location with four 5x20 self-tapping screws. Mounting plate φ6 Fixing hole Four places...
  • Page 39 www.reelschematic.com www.reelschematic.com 4. Fasten fixing plates (left, right) to the facsimile with six M4x15 pan head screws. Fixing plate (right) Fixing plate (left) M4x15 Six places Facsimile 5. Attach the compass safe distance label at the location shown below. Compass safe distance label...
  • Page 40 www.reelschematic.com www.reelschematic.com Changing modem settings 1. Press [Menu/set], [ ], [2], [8], [6] and [4] keys in this sequence to enter the maintenance mode. The fax machine beeps for approx. one sec and displays “MAINTENANCE” on the LCD. This means it is in the initial stage of the maintenance mode. 2.
  • Page 41: Telephone Fc755D1

    www.reelschematic.com www.reelschematic.com Telephone FC755D1 General The telephone can be installed on a desktop or a bulkhead. Select a location where the telephone can easily be operated. • For installation on a wooden table, use the mounting base and self-tapping screws (supplied).
  • Page 42: Serial Printer Ml280S

    www.reelschematic.com www.reelschematic.com 4. Set the telephone to the four catches in the mounting base and then slide it toward you until you hear a click. 5. Attach the “SLIDE” label (supplied) to the handset. 6. Attach English language label (supplied) to the telephone. 7.
  • Page 43: Terminal Adapter (Qdgy911912) Setting

    www.reelschematic.com www.reelschematic.com Terminal Adapter (QDGY911912) Setting The terminal adapter is used to connect analog devices to the ISDN port. The analog device supports 4.8k speech and 9.6kbps fax. All programming of the terminal adapter is done with the analog telephone/fax connected to the terminal adapter to be programmed (except PIN code which can be programmed from any port).
  • Page 44 www.reelschematic.com www.reelschematic.com...
  • Page 45 www.reelschematic.com www.reelschematic.com...
  • Page 46: Packing Lists

    www.reelschematic.com www.reelschematic.com PACKING LIST 16AI‑X‑9854 ‑1  FAX‑2820 N A M E DESCRIPTION/CODE № O U T L I N E Q'TY ユニット UNIT FAX(エイブン CE) FAX‑2820 FACSIMILE MACHINE 000‑156‑880 工事材料 INSTALLATION MATERIALS 工事材料 CP16‑03504 INSTALLATION MATERIALS 004‑450‑540 工事材料 INSTALLATION MATERIALS 固定板(右)組品 CP16‑03502 FIXING PLATE ASSY. 004‑450‑520 CP16‑03503 固定板(左)組品 FIXING PLATE ASSY. 004‑450‑530 CP16‑03501 取付板組品 MOUNTING PLATE ASSY. 004‑450‑510 図書 DOCUMENT FAX取付方法 C52‑00204‑* FAX INSTALLATION PROCEDURES 000‑146‑784 (略図の寸法は、参考値です。  DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)...
  • Page 47 www.reelschematic.com www.reelschematic.com 004‑450‑540 16AI‑X‑9412 ‑1  CODE NO. TYPE CP16‑03504 工事材料表 For FAX-2820 INSTALLATION MATERIALS 番 号 名  称  型名/規格 数量 略  図 用途/備考 Q'TY OUTLINE  NO.  NAME DESCRIPTIONS REMARKS ハリマーク(INMAR) 16‑007‑6919‑0 LABEL (INMAR) CODE NO. 100‑217‑010 16‑007‑6927‑0 ハリマーク LABEL CODE NO. 100‑222‑480 フックオサエイタ 16‑011‑4301 HOOK RETENTION PLATE CODE NO. 100‑330‑470 +トラスタッピンネジ 1種 5X20 SUS304 SELF‑TAPPING SCREW CODE NO.
  • Page 48 www.reelschematic.com www.reelschematic.com 004‑438‑410 16AG‑X‑9412 ‑0  CODE NO. CODE NO. CODE NO. CODE NO. TYPE TYPE TYPE TYPE CP16‑00511 工事材料表 工事材料表 For Telephone FC755D1 工事材料表 工事材料表 INSTALLATION MATERIALS 番 号 名  称  型名/規格 数量 略  図 用途/備考 Q'TY OUTLINE  NO.  NAME DESCRIPTIONS REMARKS ハリマーク(SLIDE) 16‑007‑6405‑0 LABEL(SLIDE) CODE NO. 100‑222‑470 ハリマーク(INMAR) 16‑007‑6919‑0 LABEL (INMAR) CODE NO.
  • Page 49 www.reelschematic.com www.reelschematic.com 004‑438‑420 16AG‑X‑9413 ‑0  CODE NO. CODE NO. CODE NO. CODE NO. TYPE TYPE TYPE TYPE CP16‑00512 工事材料表 工事材料表 For Telephone FC755D1 工事材料表 工事材料表 INSTALLATION MATERIALS 番 号 名  称  型名/規格 数量 略  図 用途/備考 Q'TY OUTLINE  NO.  NAME DESCRIPTIONS REMARKS 取付板 16‑011‑7102‑0 MOUNTING BASE CODE NO. 100‑273‑840 +トラスタッピンネジ 4X16 SUS304 1シュ +TAPPING SCREW CODE NO.
  • Page 50 www.reelschematic.com www.reelschematic.com Y. Hatai...
  • Page 51 www.reelschematic.com www.reelschematic.com...
  • Page 52 www.reelschematic.com www.reelschematic.com...
  • Page 53 www.reelschematic.com www.reelschematic.com...
  • Page 54 www.reelschematic.com www.reelschematic.com...
  • Page 55 www.reelschematic.com www.reelschematic.com...
  • Page 56 www.reelschematic.com www.reelschematic.com T.Matsuguchi Feb.15'06...
  • Page 57 www.reelschematic.com www.reelschematic.com Y. Hatai...
  • Page 58: Interconnection Diagram

    100VAC E‑300 *1)造船所手配。 *2)オプション。 200‑230VAC 1φ,50‑60Hz *3)コネクタプラグは工場にて取付済み。 *4)1ポート当り延長できる総ケーブル長は100m。 *5)RS‑422またはRS‑232Cをメニューで選択。 L3000,3m *6)固定用ボルトを介して接地する。 NOTE DRAWN TITLE FELCOM 50 T.YAMASAKI Sep. 14 '05 SHIPYARD SUPPLY. CHECKED 名称 インマルサットFLEET F55 船舶地球局 OPTION. T.TAKENO Sep. 14 '05 CONNECTOR PLUG FITTED AT FACTORY. APPROVED 相互結線図 Sep. 15 '05 CABLE LENGTH FOR ONE PORT UP TO 100m.