5.
Bend and connect the short exhaust hose (1) provided with the air filtration unit to the
exhaust port on the back of the laser system and secure it with the provided hose clamps.
Once the hose is attached, install the provided sheet metal cover over the exhaust hose.
6.
Attach a power cord to the air filtration unit's power inlet (5), but do not plug into power outlet
at this point.
7.
Connect the provided 3 ft. communications cable between one of the two Serial ports (2) of
the laser system and the Serial port connector on the air filtration unit (3). Secure the
Serial cable using the retainer clips (4).
8.
Attach a power cord to the laser system's power inlet (6), but do not plug into power outlet at
this point.
9.
Continue to next section.
Laser System Assembly
1. Unpack the laser system, place it on the table or desktop where you intend to operate it (if not
using the optional exhaust air filtration unit) and open the top door and remove any packaging
from inside the machine.
2. Gently move the X-Axis arm back and forth. It should slide freely, if all packing material
has been removed.