Page 1
FR3200 Series Hi Flow DC Pump Service Instructions Bypass Valve Service Procedure WARNING! Disconnect electrical power and relieve any pressure in the lines prior to servicing this pump! Failure to do so can result in damage to the equipment and personal injury or death! IMPORTANT! Removal of the bypass valve in the FR3210 requires special attention;...
Page 2
Servicing the Bypass Valve (cont’d) The bypass valve is located inside the pump housing. It is accessed through the inlet and outlet openings. The bypass valve consists of three components (Figure 3): A. Bypass Valve Retainer B. Bypass Valve Spring C.
Page 3
Re-Installation of the Bypass Valve (cont’d) Figure 5 The Valve Retainer requires a push and turn motion to be installed. Needle nose pliers at least 4” in length are required for this procedure. IMPORTANT! Use of a small flashlight will help you better see and more easily align the components in this task.