SEMICONDUCTORS
Only major semiconductors are shown, general semiconductors etc. are omitted to list.
The semiconductor which described a detailed drawing in a schematic diagram are omitted to list.
1. IC's
R5F100MFAFA (U1004)
PORT TABLE
Pin
Port
I/O use
1
P141/PCLBUZ1/INTP7
I/O
I
PROT_1
2
P140/PCLBUZ0/INTP6
I/O
I
PROT_2
3
P120/ANI19
I/O
O
4
P45/SO01
I/O
O
5
P44/SI01/SDA01
I/O I/O
6
P43/SCK01/SCL01
I/O
O
7
P42/TI04/TO04
I/O
I
HP_DET
8
P41/TI07/TO07
I/O
O
AMPON
9
P40/TOOL0
I/O I/O
10
RESET
I
I
11
P124/XT2/EXCLKS
I
I
12
P123/XT1
I
I
13
P137/INTP0
I
I
14
P122/X2/EXCLK
I
I
15
P121/X1
I
I
16
REGC
-
-
17
VSS
-
-
18
EVSS0
-
-
19
VDD
-
-
20
EVDD0
-
-
21
P60/SCLA0
I/O
O
22
P61/SDAA0
I/O
O
23
P62/SCLA1
I/O
I
24
P63/SDAA1
I/O
O
25
P31/TI03/TO03/INTP4
I/O
I
26
P64/TI10/TO10
I/O
I
27
P65/TI11/TO11
I/O
O
LED_BL
28
P66/TI12/TO12
I/O
O
29
P67/TI13/TO13
I/O
O
30
P77/KR7/INTP11
I/O
I
31
P76/KR6/INTP10
I/O
I
32
P75/KR5/INTP9
I/O
I
32
Port Setting
Name
Note
Act. stby
Exit R
L
-
PU 47k DC detection
L
-
PU 47k Power-failure detection
PRT_
L
L
PD 10K Output H at startup, reset additional protection circuit
RST
NC
L
L
-
SDA
L
H
-
E2PROM Serial Data Spare
SCL
L
H
-
E2PROM Serial Clock Spare
L
-
PU 10k Headphone Detection (Detected:L)
H
L
PD 10k NC500 ON/OFF (ON:H)
TEST
H
-
PU 10k
L->H:PROGRAM MODE
PU
RESET
L
-
Reset
100k
XT2
-
-
PD 47k Sub Clock (32.758kHz) Spare
XT1
-
-
PD 47k Sub Clock (32.758kHz) Spare
Detect Power Down (Power outage detection)
P_
(Primary power ON / OFF detection) Monitoring on
L
-
PD 47k
DOWN
power failure
L detects P_Down detection
X2
-
-
PD 47k Main System Clock (8MHz) Spare
X1
-
-
PD 47k Main System Clock (8MHz) Spare
REGC
-
-
-
Regulator Capacitance
VSS
-
-
-
GND
EVSS0
-
-
-
GND
VDD
-
-
-
3.3V
EVDD0
-
-
-
3.3V
NC
L
L
-
SP_
H
-
-
Speaker relay control Spare
RELAY
CLIP
L
-
PU 10k NC500 Clip detection (H/L=Normal/Clip)
Time_
DC detection time constant switching
H
L
PU 10K
Const
H/L = Small time constant/Large time constant
SC-
NC500 Overcurrent detection (H/L=Normal/Trigger)
L
-
PU 10k
CPIND
ALC Trigger input
RC5_IN
L
-
PU 33k RC5 Capture input
H
L
PD 10k LCD Backlight (H:BackLight on)
LCD-Controler (ST7032) Resister Select
L_RS
-
-
-
H/L = Data/Instruction
L_RES
PU 22k LCD-Controler (ST7032) Reset
PD
INT
H
-
Input Selector Interrupt
100k
FATAL
H
-
PD 47k NC500 DC detection (H/L=FATAL/Normal)
VOL_B
H
-
PU 10k Volume Rotary Encorder

Hide quick links: