EP1518-0002
EtherCAT Box with 8 digital inputs and 2 counters
2022-09-19 | Version: 2.4

Advertisement

Table of Contents
loading

Summary of Contents for Beckhoff EP1518-0002

  • Page 1 Documentation | EN EP1518-0002 EtherCAT Box with 8 digital inputs and 2 counters 2022-09-19 | Version: 2.4...
  • Page 3: Table Of Contents

    5.5.2 Object description and parameterization................ 47 6 Appendix .............................. 56 General operating conditions ...................... 56 Accessories .............................  57 Version identification of EtherCAT devices .................. 58 6.3.1 General notes on marking.................... 58 6.3.2 Version identification of EP/EPI/EPP/ER/ERI boxes............ 59 EP1518-0002 Version: 2.4...
  • Page 4 Table of contents 6.3.3 Beckhoff Identification Code (BIC) ...................  60 6.3.4 Electronic access to the BIC (eBIC).................  62 Support and Service........................ 64 Version: 2.4 EP1518-0002...
  • Page 5: Foreword

    , XTS and XPlanar are registered trademarks of and licensed by Beckhoff Automation GmbH. Other designations used in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owners. Patent Pending...
  • Page 6: Safety Instructions

    All the components are supplied in particular hardware and software configurations appropriate for the application. Modifications to hardware or software configurations other than those described in the documentation are not permitted, and nullify the liability of Beckhoff Automation GmbH & Co. KG. Personnel qualification This description is only intended for trained specialists in control, automation and drive engineering who are familiar with the applicable national standards.
  • Page 7: Documentation Issue Status

    Example with D no.: 55 09 01 00: 55 - week of production 55 09 - year of production 2009 01 - firmware version 01 00 - hardware version 001 Further information on this topic: Version identification of EtherCAT devices [} 58]. EP1518-0002 Version: 2.4...
  • Page 8: Ethercat Box - Introduction

    • digital outputs with 0.5 or 2 A output current • analog inputs and outputs with 16 bit resolution • Thermocouple and RTD inputs • Stepper motor modules XFC (eXtreme Fast Control Technology) modules, including inputs with time stamp, are also available. Version: 2.4 EP1518-0002...
  • Page 9 Fig. 3: EtherCAT Box with M12 connections for sensors/actuators Basic EtherCAT documentation You will find a detailed description of the EtherCAT system in the Basic System Documentation for EtherCAT, which is available for download from our website (www.beckhoff.com) under Downloads. EP1518-0002 Version: 2.4...
  • Page 10: Product Overview

    8 digital inputs (24 V ), 2 counters The EP1518-0002 EtherCAT Box with digital inputs acquires binary control signals from the process level and transfers them, with electrical isolation, to the controller. The signal state is indicated by means of light emitting diodes. Connection is via M12 connectors. The input filters can be set between 0 and 100 ms via EtherCAT.
  • Page 11: Technical Data

    -40 … +85 °C Vibration resistance, shock resistance conforms to EN 60068-2-6 / EN 60068-2-27 Additional checks [} 13] EMC immunity / emission conforms to EN 61000-6-2 / EN 61000-6-4 Protection class IP65, IP66, IP67 (conforms to EN 60529) Approvals / markings Approvals / markings  ATEX, CE, cURus [} 24] EP1518-0002 Version: 2.4...
  • Page 12 Product overview *) Real applicable approvals/markings see type plate on the side (product marking). Version: 2.4 EP1518-0002...
  • Page 13: Scope Of Supply

    Scope of supply Make sure that the following components are included in the scope of delivery: • 1x EtherCAT Box EP1518-0002 • 2x protective cap for EtherCAT socket, M8, green (pre-assembled) • 1x protective cap for supply voltage input, M8, transparent (pre-assembled) •...
  • Page 14: Process Image

    Alternatively the counter can be disabled or enabled by the physical GATE input. The two values are XORed. The output data of the 2nd counter can be found under CNT Output Channel 1. Their structure corresponds to that of the 1st counter. Version: 2.4 EP1518-0002...
  • Page 15 Error channel 1 displays a short circuit of the supply voltage Us to digital inputs 0 to 3. Error channel 2 displays a short circuit of the supply voltage Us to digital inputs 4 to 7. EP1518-0002 Version: 2.4...
  • Page 16: Installation

    CuZn, gold-plated Power feed through max. 4 A Installation position variable Protection class IP65, IP66, IP67 (conforms to EN 60529) when screwed together Dimensions (H x W x D) approx. 126 x 30 x 26.5 mm (without connectors) Version: 2.4 EP1518-0002...
  • Page 17: Fixing

    Mount the module with two M3 screws on the mounting holes in the corners of the module. The mounting holes have no thread. 4.1.3 Tightening torques for plug connectors Screw connectors tight with a torque wrench. (e.g. ZB8801 from Beckhoff) Connector diameter Tightening torque 0.4 Nm 0.6 Nm...
  • Page 18: Connection

    For standardization, the core colors of the ZB9030, ZB9032 and ZK1090-3xxx-xxxx cables have been changed to the EN61918 core colors: yellow, orange, white, blue. So there are different color codes in circulation. The electrical properties of the cables have been retained when the core colors were changed. Version: 2.4 EP1518-0002...
  • Page 19 (CAT5) according to EN 50173 or ISO/IEC 11801 should be used. EtherCAT uses four wires for signal transmission. Thanks to automatic line detection ("Auto MDI-X"), both symmetrical (1:1) or cross-over cables can be used between Beckhoff EtherCAT. Detailed recommendations for the cabling of EtherCAT devices EP1518-0002...
  • Page 20: Supply Voltages

    In some types of EtherCAT Box modules the ground potentials GND and GND are connected. • If several EtherCAT Box modules are supplied with the same electrically isolated voltages, check whether there is an EtherCAT Box among them in which the ground potentials are connected. Version: 2.4 EP1518-0002...
  • Page 21 Function Description Core color Control voltage Brown Peripheral voltage White Blue Black The core colors apply to cables of the type: Beckhoff ZK2020-3xxx-xxxx 4.2.2.2 Status LEDs Display Meaning (control voltage) The supply voltage U is not available. green illuminated The supply voltage U is available.
  • Page 22 Vert. Faktor: 0,45 cm / V Vert. Faktor: 0,4 0,34 mm² Vert. Faktor: 0,45 cm / V Vert. Faktor: 0,5 mm² 0,25 mm² 0,34 mm² 0,75 mm² 0,5 mm² 0,75 mm² Cable length (m) Cable length (m) Version: 2.4 EP1518-0002...
  • Page 23: Signal Connection

    Use the sensor supply at pin 1 as supply voltage for connected sensors. Specifications [} 11]. Connection examples Status LEDs Each M12 socket has two green LEDs. An LED lights up when a high level is detected at the respective input. Input A Input B EP1518-0002 Version: 2.4...
  • Page 24: Ul Requirements

    To meet the UL requirements, EtherCAT Box Modules has to be operated only at an ambient temperature range of -25 °C to +55 °C! Marking for UL All EtherCAT Box Modules certified by UL (Underwriters Laboratories) are marked with the following label. Fig. 6: UL label Version: 2.4 EP1518-0002...
  • Page 25: Atex Notes

    FF - firmware version HH - hardware version Example with batch number 29 10 02 01: 29 - week of production 29 10 - year of production 2010 02 - firmware version 02 01 - hardware version 01 EP1518-0002 Version: 2.4...
  • Page 26: Bg2000 - Ethercat Box Protection Enclosures

    EtherCAT Box. Installation Put the cables for EtherCAT, power supply and sensors/actuators through the hole of the protection enclosure. Fig. 7: BG2000 - putting the cables Fix the wires for EtherCAT, power supply and sensors/actuators to the EtherCAT Box. Version: 2.4 EP1518-0002...
  • Page 27: Atex Documentation

    Notes about operation of EtherCAT Box Modules (EPxxxx-xxxx) in potentially explo- sive areas (ATEX) Pay also attention to the continuative documentationNotes about operation of EtherCAT Box Mod- ules (EPxxxx-xxxx) in potentially explosive areas (ATEX) that is available in the download area of the Beckhoff homepage http:\\www.beckhoff.com! EP1518-0002 Version: 2.4...
  • Page 28: Disposal

    Products marked with a crossed-out wheeled bin shall not be discarded with the normal waste stream. The device is considered as waste electrical and electronic equipment. The national regulations for the disposal of waste electrical and electronic equipment must be observed. Version: 2.4 EP1518-0002...
  • Page 29: Commissioning And Configuration

    Commissioning and configuration Commissioning and configuration Integrating into a TwinCAT project The procedure for integration in a TwinCAT project is described in these Quick start guide. EP1518-0002 Version: 2.4...
  • Page 30: Distributed Clocks (Dc)

    EtherCAT datagram. This setting may be useful in systems with high real-time jitter, if no Industrial PCs from Beckhoff are used for control purposes, for example. Version: 2.4...
  • Page 31 Sync Unit cycle: a multiple of the bus cycle time. The counter value is periodically determined at this interval (in µs). User defined Any number up to 2 ns, or about 4.3 seconds. Use of decimal points is allowed. EP1518-0002 Version: 2.4...
  • Page 32: Distributed Clocks And Ep1518

    Distributed Clocks and EP1518 Digital inputs and Distributed Clocks If the Distributed Clock of the EP1518 is activated, the digital inputs are read in without the set filter promptly before the arrival of the querying EtherCAT datagram. Version: 2.4 EP1518-0002...
  • Page 33: Configuration

    Basic Function Principles The EP1518-0002 has 8 digital inputs. Of these, inputs 0, 1 and 2 as well as 4, 5 and 6 can each be used for one counter. The states of the individual inputs are always illustrated in the process image, irrespective of their use.
  • Page 34 In the default setting the counter is disabled by applying a high level to the GATE input or by setting the Inhibit Counters bit Setting the CoE object 0x80x0:05 Enable input gate activates the counter if GATE is set and deactivates it if GATE is not set. Version: 2.4 EP1518-0002...
  • Page 35 Commissioning and configuration Fig. 15: Counting mode with inverted GATE input Fig. 16: CoE for inverting the GATE input EP1518-0002 Version: 2.4...
  • Page 36: Operation Modes

    The second counter is always active internally Internally the second counter is always active, so that when switching from one 32-bit counter to two 32-bit counters the previous incoming pulses were counted in the second counter and saved in the Counter Value. Version: 2.4 EP1518-0002...
  • Page 37 This is the operation mode in the factory setting. The PDOs 0x1600 [} 49], 0x1601 [} 50] as well as 0x1A00 [} 50], 0x1A01 [} 50], 0x1A02 [} 51] and 0x1A03 [} 51] are activated. The meaning of the individual objects is explained in the object description. EP1518-0002 Version: 2.4...
  • Page 38 One up/down counter This mode can be set as follows: The PDOs 0x1600 [} 49] as well as 0x1A00 [} 50], 0x1A02 [} 51] and 0x1A03 [} 51] are activated. The CoE objects are identical to the 2 x 32-bit counter operation mode. Version: 2.4 EP1518-0002...
  • Page 39 Commissioning and configuration 8 digital inputs, no counter This mode can be set as follows: The PDOs 0x1A02 [} 51] and 0x1A03 [} 51] are activated. The meaning of the individual objects is explained in the object description. EP1518-0002 Version: 2.4...
  • Page 40: Counter Settings

    If a desired value is set in Counter reload value and the Enable reload bit is activated, the counter is set to 0 or to the set value if the specified value is exceeded or fallen below (depending on the counting direction). Version: 2.4 EP1518-0002...
  • Page 41 Commissioning and configuration Fig. 19: Automatic setting of the counter EP1518-0002 Version: 2.4...
  • Page 42: Restoring The Delivery State

    Fig. 21: Entering a restore value in the Set Value dialog Alternative restore value In some older terminals / boxes the backup objects can be switched with an alternative restore value: Decimal value: 1819238756 Hexadecimal value: 0x6C6F6164 An incorrect entry for the restore value has no effect. Version: 2.4 EP1518-0002...
  • Page 43: Coe Objects

    EtherCAT XML Device Description The display matches that of the CoE objects from the EtherCAT XML Device Description. We rec- ommend downloading the latest XML file from the download area of the Beckhoff website and in- stalling it according to installation instructions.
  • Page 44 SubIndex 001 0x1600 (5632 [} 51] 1C12:02 SubIndex 002 0x1601 (5633 Subindex TxPDO assign 0x04 (4 1C13:0 1C13:01 SubIndex 001 0x1A00 (6656 [} 52] 1C13:02 SubIndex 002 0x1A01 (6657 1C13:03 SubIndex 003 0x1A02 (6658 1C13:04 SubIndex 004 0x1A03 (6659 Version: 2.4 EP1518-0002...
  • Page 45 Counter inhibited 0x00 (0 6010:05 Status of input UD 0x00 (0 6010:06 Status of input clock 0x00 (0 6010:0E Sync error 0x00 (0 6010:0F TxPDO State 0x00 (0 6010:10 TxPDO Toggle 0x00 (0 6010:11 Counter value 0x00000000 (0 EP1518-0002 Version: 2.4...
  • Page 46 0x0010 (16 F000:02 Maximum number of modules 0x0003 (3 Code word 0x00000000 (0 F008 [} 55] Subindex Module list 0x03 (3 F010:0 [} 55] F010:01 SubIndex 001 0x00000096 (150 F010:02 SubIndex 002 0x00000096 (150 F010:03 SubIndex 003 0x00000118 (280 Version: 2.4 EP1518-0002...
  • Page 47: Object Description And Parameterization

    EtherCAT XML Device Description The display matches that of the CoE objects from the EtherCAT XML Device Description. We rec- ommend downloading the latest XML file from the download area on the Beckhoff website (http:// www.beckhoff.de/german/default.htm?download/elconfg.htm) and installing it according to the in- stallation instructions.
  • Page 48 0x8022:01 [} 48] 8022:05 Input 4 UINT8 0x00 (0 see 0x8022:01 [} 48] 8022:06 Input 5 UINT8 0x00 (0 see 0x8022:01 [} 48] 8022:07 Input 6 UINT8 0x00 (0 see 0x8022:01 [} 48] 8022:08 Input 7 UINT8 0x00 (0 see 0x8022:01 [} 48] Version: 2.4 EP1518-0002...
  • Page 49 Index (hex) Name Meaning Data type Flags Default 1008:0 Device name Device name of the EtherCAT slave STRING EP1518-0002 Index 1009 Hardware version Index (hex) Name Meaning Data type Flags Default 1009:0 Hardware version Hardware version of the EtherCAT slave...
  • Page 50 SubIndex 009 9. PDO Mapping entry (object 0x6020 (CNT Inputs), en- UINT32 0x6010:10, 1 try 0x10 (TxPDO Toggle)) 1A01:0A SubIndex 010 10. PDO Mapping entry (object 0x6010 (CNT Inputs), en- UINT32 0x6010:11, 32 try 0x11 (Counter value)) Version: 2.4 EP1518-0002...
  • Page 51 0x02 (2 1C12:01 Subindex 001 1. allocated RxPDO (contains the index of the associated UINT16 0x1600 RxPDO mapping object) (5632 1C12:02 Subindex 002 2. allocated RxPDO (contains the index of the associated UINT16 0x1601 RxPDO mapping object) (5633 EP1518-0002 Version: 2.4...
  • Page 52 Shift too short counter Number of occasions that the interval between SYNC0 UINT16 0x0000 (0 and SYNC1 event was too short (DC mode only) 1C32:20 Sync error The synchronization was not correct in the last cycle BOOLEAN 0x00 (0 (outputs were output too late; DC mode only) Version: 2.4 EP1518-0002...
  • Page 53 1C33:0B SM event missed as 0x1C32:11 UINT16 0x0000 (0 counter 1C33:0C Cycle exceeded as 0x1C32:12 UINT16 0x0000 (0 counter 1C33:0D Shift too short counter as 0x1C32:13 UINT16 0x0000 (0 1C33:20 Sync error as 0x1C32:32 BOOLEAN 0x00 (0 EP1518-0002 Version: 2.4...
  • Page 54 The counter is stopped, as long as this bit is active. The BOOLEAN 0x00 (0 previous counter state is retained. 7000:11 Set counter value This is the counter value to be set via “Set counter” (in- UINT32 0x00000000 dex 0x7000:03 [} 54]). Version: 2.4 EP1518-0002...
  • Page 55 Validity of the data of the associated TxPDO (0 = valid, 1 BOOLEAN 0x00 (0 = invalid) F600:10 TxPDO Toggle The TxPDO toggle is toggled by the slave when the data BOOLEAN 0x00 (0 of the associated TxPDO is updated EP1518-0002 Version: 2.4...
  • Page 56: Appendix

    (ph-Value > 12) > 40°C: not resistant Acetic acid not resistant Argon (technical clean) resistant • resistant: Lifetime several months • non inherently resistant: Lifetime several weeks • not resistant: Lifetime several hours resp. early decomposition Version: 2.4 EP1518-0002...
  • Page 57: Accessories

    Torque cable key for M12 / wrench size 13 for ZB8801-0000 ZB8801-0003 Torque cable key for M12 field assembly / wrench size 18 for ZB8801-0000 Further accessories Further accessories can be found in the price list for fieldbus components from Beckhoff and online at https://www.beckhoff.com. EP1518-0002 Version: 2.4...
  • Page 58: Version Identification Of Ethercat Devices

    Associated and synonymous with each revision there is usually a description (ESI, EtherCAT Slave Information) in the form of an XML file, which is available for download from the Beckhoff web site. From 2014/01 the revision is shown on the outside of the IP20 terminals, see Fig. “EL5021 EL terminal, standard IP20 IO device with batch number and revision ID (since 2014/01)”.
  • Page 59: Version Identification Of Ep/Epi/Epp/Er/Eri Boxes

    Version identification of EP/EPI/EPP/ER/ERI boxes The serial number/ data code for Beckhoff IO devices is usually the 8-digit number printed on the device or on a sticker. The serial number indicates the configuration in delivery state and therefore refers to a whole production batch, without distinguishing the individual modules of a batch.
  • Page 60 6.3.3 Beckhoff Identification Code (BIC) The Beckhoff Identification Code (BIC) is increasingly being applied to Beckhoff products to uniquely identify the product. The BIC is represented as a Data Matrix Code (DMC, code scheme ECC200), the content is based on the ANSI standard MH10.8.2-2016.
  • Page 61 Fig. 24: Example DMC 1P072222SBTNk4p562d71KEL1809 Q1 51S678294 An important component of the BIC is the Beckhoff Traceability Number (BTN, position 2). The BTN is a unique serial number consisting of eight characters that will replace all other serial number systems at Beckhoff in the long term (e.g.
  • Page 62 Electronic access to the BIC (eBIC) Electronic BIC (eBIC) The Beckhoff Identification Code (BIC) is applied to the outside of Beckhoff products in a visible place. If possible, it should also be electronically readable. Decisive for the electronic readout is the interface via which the product can be electronically addressed.
  • Page 63 EtherCAT, the eBIC of the top-level device is located in the CoE object directory 0x10E2:01 and the eBICs of the sub-devices follow in 0x10E2:nn. Profibus/Profinet/DeviceNet… Devices Currently, no electronic storage and readout is planned for these devices. EP1518-0002 Version: 2.4...
  • Page 64 Please contact your Beckhoff branch office or representative for local support and service on Beckhoff products! The addresses of Beckhoff's branch offices and representatives round the world can be found on her internet pages: https://www.beckhoff.com You will also find further documentation for Beckhoff components there.
  • Page 66 More Information: www.beckhoff.com/ep1518/ Beckhoff Automation GmbH & Co. KG Hülshorstweg 20 33415 Verl Germany Phone: +49 5246 9630 info@beckhoff.com www.beckhoff.com...

Table of Contents