Sign In
Upload
Manuals
Brands
Beckhoff Manuals
I/O Systems
EP1518-0002
Beckhoff EP1518-0002 Manuals
Manuals and User Guides for Beckhoff EP1518-0002. We have
2
Beckhoff EP1518-0002 manuals available for free PDF download: Documentation
Beckhoff EP1518-0002 Documentation (73 pages)
EtherCAT Box with 8 digital inputs and 2 counters
Brand:
Beckhoff
| Category:
I/O Systems
| Size: 3.1 MB
Table of Contents
Table of Contents
3
1 Foreword
5
Notes on the Documentation
5
Safety Instructions
6
Documentation Issue Status
7
2 Product Overview
8
Ethercat Box - Introduction
8
Fig. 1 Ethercat Box Modules Within an Ethercat Network
8
Fig. 2 Ethercat Box with M8 Connections for Sensors/Actuators
9
Fig. 3 Ethercat Box with M12 Connections for Sensors/Actuators
9
EP1518 - Introduction
10
Fig. 4 EP1518-0001 and EP1518-0002
10
EP1518 - Technical Data
11
EP1518 - Process Image
12
3 Installation
14
Mounting
14
Dimensions
14
Fig. 5 Dimensions of the Ethercat Box Modules
14
Fixing
15
Fig. 6 Mounting Rail ZS5300-000
15
Nut Torque for Connectors
16
Fig. 7 Ethercat Box with M8 Connectors
16
Fig. 8 Ethercat Box with M8 and M12 Connectors
16
Fig. 9 7/8" Plug Connectors
17
Fig. 10 ZB8801 Torque Socket Wrench
17
Connection
18
Ethercat Connection
18
Fig. 11 Ethercat Box: M8, 30 MM Housing
18
Fig. 12 Ethercat Box: M860 MM Housing (Example: EP9214)
18
Fig. 13 Coupler Box: M12
18
Ethercat - Fieldbus Leds
19
Fig. 14 Ethercat-Leds
19
Power Connection
21
Fig. 15 Ethercat Box, Connectors for Power Supply
21
Fig. 16 Pin Assignment M8, Power in and Power out
21
Fig. 17 Ep92X4-0023, Connectors for Power in and Power out
23
Fig. 18 Pin Assignment 7/8", Power in and Power out
23
EP1518 - Status Leds for the Power Supply
24
Fig. 19 Status Leds for the Power Supply
24
Power Cables
25
Power Cable Conductor Losses M8
26
Fig. 20 Power Cable Conductor Losses
26
Signal Connection
27
Fig. 21 Signal Connection - Digital Inputs M8 and M12
27
Status Leds at the Signal Connections
28
Fig. 22 Status Leds at the Signal Connections
28
UL Requirements
29
Fig. 23 UL Label
29
ATEX Notes
30
ATEX - Special Conditions
30
BG2000-0000 - Ethercat Box Protection Enclosure
31
Fig. 24 BG2000-0000, Putting the Cables
31
Fig. 25 BG2000-0000, Fixing the Cables
31
ATEX Documentation
32
Fig. 26 BG2000-0000, Mounting the Protection Enclosure
32
4 Commissioning and Configuration
33
Integration in Twincat
33
Inserting into the Ethercat Network
33
Fig. 27 Scanning in the Configuration (I/O Devices -> Right-Click -> Scan Devices
33
Fig. 28 Appending a New I/O Device (I/O Devices -> Right-Click -> Append Device
34
Fig. 29 Selecting the Device Ethercat
34
Fig. 30 Appending a New Box (Device -> Right-Click -> Append Box
34
Fig. 31 Selecting a Box (E.g. EP2816-0008)
35
Fig. 32 Appended Box in the Twincat Tree
35
Configuration Via Twincat
36
Fig. 33 Branch of the Ethercat Box to be Configured
36
Fig. 34 General Tab
36
Fig. 35 Ethercat Tab
37
Fig. 36 Process Data Tab
38
Fig. 37 Startup Tab
40
Fig. 38 Coe - Online Tab
41
Fig. 39 Advanced Settings
42
Fig. 40 Online Tab
42
Distributed Clocks (DC)
44
Fig. 41 DC Tab (Distributed Clocks)
44
Fig. 42 Advanced Settings for Distributed Clocks (DC)
45
Distributed Clocks and EP1518
46
Fig. 43 Ethercat Master, Ethercat Tab, Advanced Settings
46
Configuration of the EP1518
47
Basic Function Principles
47
Fig. 44 Counting Mode with Standard Setting
47
Operation Modes
49
Counter Settings
53
Restoring the Delivery State
55
Coe Objects
56
Object Overview
56
Object Description and Parameterization
60
5 Appendix
69
Ethercat Box- / Ethercat P Box - Accessories
70
Support and Service
71
List of Illustrations
72
Advertisement
Beckhoff EP1518-0002 Documentation (66 pages)
EtherCAT Box with 8 digital inputs and 2 counters
Brand:
Beckhoff
| Category:
Network Hardware
| Size: 3.02 MB
Table of Contents
Table of Contents
3
Foreword
5
Notes on the Documentation
5
Safety Instructions
6
Documentation Issue Status
7
Ethercat Box - Introduction
8
Product Overview
10
Introduction
10
Technical Data
11
Scope of Supply
13
Process Image
14
Installation
16
Mounting
16
Dimensions
16
Fixing
17
Tightening Torques for Plug Connectors
17
Connection
18
Ethercat
18
Supply Voltages
20
Signal Connection
23
UL Requirements
24
ATEX Notes
25
ATEX - Special Conditions
25
BG2000 - Ethercat Box Protection Enclosures
26
ATEX Documentation
27
Disposal
28
Commissioning and Configuration
29
Integrating into a Twincat Project
29
Distributed Clocks (DC)
30
Distributed Clocks and EP1518
32
Configuration
33
Basic Function Principles
33
Operation Modes
36
Counter Settings
40
Restoring the Delivery State
42
Coe Objects
43
Object Overview
43
Object Description and Parameterization
47
Appendix
56
General Operating Conditions
56
Accessories
57
Version Identification of Ethercat Devices
58
General Notes on Marking
58
Version Identification of EP/EPI/EPP/ER/ERI Boxes
59
Advertisement
Related Products
Beckhoff EP1518-0001
Beckhoff EPI2008-0001
Beckhoff EPI1008-0001
Beckhoff EPP2008-0001
Beckhoff EPP2318-0001
Beckhoff EPP2328-0001
Beckhoff EPP2334-0061
Beckhoff EP4378-1022
Beckhoff EPP2339-0022
Beckhoff EPP2338-2002
Beckhoff Categories
Touch terminals
Industrial PC
Control Unit
Touch Panel
Power Supply
More Beckhoff Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL