You can reset the settings to the factory default settings or
restrict operations.
1. Press the FUNCTION button, and then press the MENU
button within 10 seconds.
FUNCTION
ALL RESET
ADJUSTMENT LOCK
ADJUSTMENT LOCK TARGET
RS-232C/LAN
OSD DISPLAY
LED
TEMPERATURE ALERT
STATUS ALERT
POWER BUTTON
EXTERNAL CONTROLLER INPUT
SIGNAL RESPONSE LEVEL
APPLICATION
APPLICATION RECOVERY MODE
UPDATE MAIN SOFTWARE
2. Select and set the items.
ALL RESET
Resets the settings to the factory default settings.
Press the ENTER button, select the resetting method,
and then press the ENTER button.
After initialization, turn the main power switch off and
then back on.
ALL RESET 1:
Resets all the settings to the factory default settings.
In APPLICATION mode, only the settings of the
factory-installed applications are initialized.
ALL RESET 2:
Returns the settings to the factory default settings.
However, the following items are not returned:
REMOTE No., MONITOR CONTROL SELECT,
BAUD RATE, APPLICATION
(see pages 35 and 44.);
the applications of APPLICATION mode also are not
returned.
ADJUSTMENT LOCK
You can disable operations on the monitor and the
remote control unit that use buttons.
OFF ...Enables operation.
ON 1 ..Disables all operations other than turning power
on/off and FUNCTION.
ON 2 ..Only the FUNCTION operation is enabled.
Disables all operations other than FUNCTION (not
even power on/off).
ADJUSTMENT LOCK TARGET
Sets the target to prohibit operation of with
ADJUSTMENT LOCK.
REMOTE CONTROL ..... Prohibits remote control
MONITOR BUTTONS ... Prohibits monitor button
BOTH ............................. Prohibits remote control and
OFF
UNLOCKED
ON 1
ON
LED
OFF
MONITOR
1
OK:[ENTER] END:[RETURN]
operation
operation
monitor button operation
RS-232C/LAN
Specifies whether to allow control via RS-232C or LAN.
(See pages 45 and 53.)
OSD DISPLAY
Shows/hides the menu, modes and messages.
The FUNCTION screen cannot be hidden.
ON 1 .............. Shows all menus, modes and messages.
ON 2 .............. Hides messages automatically displayed
by the display. Shows messages during
operation.
OFF ............... Hides all menus, modes and messages.
LED
Specifies whether to light the power LED.
TEMPERATURE ALERT
Selects the notification method for an abnormal
temperature.
OFF ................ Do not notify about an abnormal
temperature.
OSD & LED .... When an abnormal temperature is
detected, the power LED flashes
in orange and blue alternately and
the screen displays a message:
TEMPERATURE.
LED................. When an abnormal temperature is
detected, the power LED flashes in
orange and blue alternately.
STATUS ALERT
Selects the notification method for a hardware error.
OFF ................ Do not notify about the error.
OSD & LED .... When a hardware error is detected,
the power LED illuminates in blue and
orange alternately and the screen
displays a message: STATUS [xxxx].
LED................. When a hardware error is detected,
the power LED illuminates in blue and
orange alternately.
POWER BUTTON
Normally, leave this setting as MONITOR.
When using an optional part, if instruction appears,
change the setting accordingly.
EXTERNAL CONTROLLER INPUT
Normally, you do not need to change this setting.
When using an optional part, if instruction appears,
change the setting accordingly.
SIGNAL RESPONSE LEVEL
Normally, you do not need to change this setting. Use
this option to set the level of response to signal changes.