Graco CleanShot 244160 Instructions - Parts Manual

Graco CleanShot 244160 Instructions - Parts Manual

Shut-off valve, includes rac5 517 switchtip and handtite guard, 3600 psi 24.8 mpa, 248 bar maximum working pressure

Advertisement

Quick Links

Instructions, Parts
CleanShot
Valve
For use on any Graco high pressure airless gun or extension. For professional use only.
Model 244160
Includes RAC5 517 SwitchTip
3600 psi (24.8 MPa, 248 bar) Maximum Working Pressure
Important Safety Instructions
Read all warnings and instructions in this manual before using the equipment.
Be familiar with the controls and the proper usage of the equipment.
Save these instructions.
Shut-off
TM
TM
TM
and HandTite
guard.
309314E
EN

Advertisement

Table of Contents
loading

Summary of Contents for Graco CleanShot 244160

  • Page 1 Instructions, Parts CleanShot Shut-off 309314E Valve For use on any Graco high pressure airless gun or extension. For professional use only. Model 244160 Includes RAC5 517 SwitchTip and HandTite guard. 3600 psi (24.8 MPa, 248 bar) Maximum Working Pressure Important Safety Instructions Read all warnings and instructions in this manual before using the equipment.
  • Page 2: Fire And Explosion Hazard

    Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.
  • Page 3: Personal Protective Equipment

    Do not kink or over-bend the hose. • Do not expose the hose to temperatures or to pressures in excess of those specified by Graco. • Do not use the hose as a strength member to pull or lift the equipment.
  • Page 4: Pressure Relief Procedure

    Pressure Relief Procedure Pressure Relief Procedure 4. Rotate spray valve knob counterclockwise to Follow the Pressure Relief Procedure whenever FLUSH position. you see this symbol. 5. Hold a metal part of the CleanShot firmly to the side of a grounded metal pail, and trigger the gun into the pail to relieve pressure.
  • Page 5: Installation

    Installation Installation 6. Rotate the CleanShot Shut-off Valve to any desired position within 180°. Do not use any tools. To avoid serious injury from skin injection, do not put your hand in front of the spray tip when installing or removing the spray tip and tip guard, or when rotating the CleanShot Shut-off Valve.
  • Page 6 Parts Parts CleanShot Repair Kit 244162 (31) Torque 26–32 ft-lb Swivel Repair Kit 244363 (35) Valve Body Kit 245687 (36) Torque 55–60 in-lb Torque 26–32 ft-lb * 36 Valve Body Kit must be purchased separately ti0947b 309314E...
  • Page 7: Parts List

    Parts List Parts List Ref. Part Description Qty. Ref. Part Description Qty. KNOB, valve 244162 KIT, CleanShot repair, includes 15H622 GASKET, non-metallic 31a-31k 244363 KIT, swivel repair SEAT, valve 244663 SWIVEL, inlet assembly GASKET 120189 NUT, cap RETAINER, ball 107505 PACKING, o-ring DAMPENER, spring 109576 PACKING, o-ring SPRING, compression...
  • Page 8: Graco Standard Warranty

    With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.

Table of Contents