Page 1
Instructions-Parts Air Actuated Dispense Valve 312782M ® To dispense plural component fluids and solvents with a ProMix proportioner. For professional use only. Low Pressure Valves Important Safety Instructions Read all warnings and instructions in this manual and in your proportioning system manual before using the equipment.
Models Models Maximum Fluid Working Maximum Air Working Part Description Pressure Pressure 15X303 High Pressure Dispense Valve 26A355 High Pressure Dispense Valve for Acid 24T785 Catalyzed Materials High Pressure Dump Valve for Acid 3000 psi (21 MPa, 207 bar) 26A313 Catalyzed Materials 100 psi (0.7 MPa, 7 bar)
Installation Installation Accessories The top installation in F . 3 shows the dispense valves installed in an electronic 2-component proportioning WARNING system. In this example, the dispense valves are used as dose valves for components A and B (DVA, DVB), an air purge valve (APV), and a solvent purge valve (SPV).
Installation Components 15X303, 24T785, and 26A355 High Pressure 15X304 Low Pressure Dispense Valves Dispense Valve Actuation indicator 5/32 in. (4 mm) OD air tube fitting, to close Optional air open port 5/32 in. (4 mm) OD air tube 5/32 in. (4 mm) OD air tube...
Page 6
Installation 24T784 4ksi High 25U791 4ksi High Pressure Dispense Valve Pressure Dispense Valve 5/32 in. (4 mm) OD air Actuation indicator tube fitting, to close 5/32 in. (4 mm) OD air tube fitting, to open Optional air open port Valve position sight port Optional air open port...
Installation Typical Installation TI12556a Iniflex ProMix 2KS configuration with Iniflex low pressure valves. . 3: Typical Installation Key: Component A Meter Component A Supply Line Component A Dose Valve Component B Supply Line Component B Meter Air Purge Line Component B Dose Valve Solvent Purge Line Flush Valve A Solvent Meter...
Installation System Pneumatic Schematic (used with ProMix 2KS) COLOR COLOR VALVE CHANGE STACKS CONTROL AIR EXHAUST MUFFLER MANIFOLD COLOR 1 COLOR 2 12 VDC COLOR 3 COLOR 4 DOSE A VALVE 4-WAY SOLENOID COLOR 5 COLOR 6 COLOR 7 COLOR 8 12 VDC COLOR SOLVENT DOSE B...
Operation Operation Maintenance Clean the Dispense Valve Daily Settings and Adjustments NOTE: Be sure the solvent used is compatible with the Set the actuating air to at least 75 psi (0.52 MPa, 5.2 fluid being dispensed, to avoid clogging the valve’s fluid bar) and start the pump.
Troubleshooting Troubleshooting Follow the Pressure Relief Procedure, page 9, before WARNING checking or repairing the equipment. NOTE: Check all possible causes and solutions before disassembling. NOTE: 26B108 valves are non-serviceable. SKIN INJECTION HAZARD High-pressure fluid from hose leaks or ruptured components will pierce skin.
Repair Repair NOTE: See Fluid Mix Manifold Manual 312781 for seat WARNING replacement instructions and part numbers. ON Port SKIN INJECTION HAZARD High-pressure fluid from hose leaks or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation.
(10) onto NOTE: Seal Kits 15U933 (for high pressure dispense the needle. valve 15X303 and 26A355), 24T817 (for acid catalyzed valves 24T785 and 26A313), and 15W621 (for low 8. Before performing step 9, screw the dispense valve...
Parts 256210 4ksi Valve Ref. Part No. Description † BODY, fluid BODY, air 3† FITTING, el male swivel, 10-32 x 5/32 AIR CAP, valve † PISTON, air 7† SPRING, compression SEAL, u-cup, spring applied BEARING, shaft, needle PACKING, o-ring PACKING, o-ring †...
With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.
Need help?
Do you have a question about the 15X303 and is the answer not in the manual?
Questions and answers