  • Page 2 The symbol opposite means that according to United Kingdom and European Union member countries laws and regulations your product and/or its battery shall be disposed of separately from household waste. When this product reaches its end of life, take it to a collection point designated by local authorities.
  • Page 3: Planning The Installation

    / MONARCH DUPLEX SERIES DUAL POWER WATER SOFTENER PROGRAMMING & INSTALLATION INSTRUCTIONS Thank you for choosing our water softener. Please read the following carefully, which if followed correctly, should ensure the installation is trouble free. / A. PLANNING THE INSTALLATION •...
  • Page 4 RAPID-FIT BYPASS INSTALLATION INSTRUCTIONS Direction arrows are embossed on the bypass as follows; SUPPLY IN - is hard water supply in from mains SUPPLY OUT - is soft water supply back to property TO UNIT - is mains hard water from bypass to softener inlet via flexi hose FROM UNIT - is soft water from the softener outlet back to bypass via flexi hose Every Rapid-Fit bypass comes with the following;...
  • Page 5 / F. WATER PRESSURE TEST • It is IMPORTANT that a pressure check is carried out. • Low and high pressure can result in either damage to, or failure of the unit. • If daytime static water pressure* exceeds 3.5 bar (50psi) a 5 bar (70psi) pressure limiter should be fitted.
  • Page 6: Drain Connection

    / H. INLET & OUTLET CONNECTIONS See Fig 2 • Remove both salt lid and main cover to access inlet and outlet connections. • Remove grey retaining clips and BSP connection points (indicated red and blue in fig 2). Connect inlet hose to male BSP connection point (indicated red in fig 2) and connect outlet hose to BSP connection (indicated blue in fig 2), using supplied washers and tighten to seal.
  • Page 7: Set Time Of Day

    / J. OVERFLOW CONNECTION - Important • The hose for the overflow should be cut from the white low pressure hose supplied with the unit. • The overflow connection is the ½” hose spigot on the rear right-hand corner of the cabinet- no jubilee clip required. •...
  • Page 8: Set Water Hardness

    / O. SET WATER HARDNESS • Wait until display changes to Hardness. • Use Up/Down buttons to set number as determined by your water hardness test. • Press to confirm setting. • You have finished the programming. • The display will now automatically revert back to the alternating display. After 30 seconds the display will go to sleep.
  • Page 9: Further Information

    / Q. EXTRA REGENERATIONS • To start an automatic regeneration, press the left hand button and release, the display will count down from 15 to zero. If at any time you wish to cancel the count down, simply press again. •...
  • Page 10 / REVERSIBLE CONNECTIONS Remove salt lid and side access panel.
  • Page 11 Remove top cover.
  • Page 12 Remove any internal packaging.
  • Page 13 Loosen the jubilee clip and disconnect the drain tubing from the elbow inside the cabinet. Then remove the complete unit. Jubilee clip...
  • Page 14 Remove the blue clip Push-fit connection Release tubing...
  • Page 15 Twist the unit supports at the top of the vessels 180 degrees. Air Check connection Unit Sup- ports Undo the large nut at the base of the main valve body, take out the valve and twist 180 degrees until the connections are on the other side.
  • Page 16 Using the supplied fittings and tubing (8cm), attach the air check Remove the small grey clip from to the valve, using the push-fit the air check connector. connector and placing the blue clip back on (as pictured). Remove the connector and ro- tate 180 degrees.
  • Page 17 Remove the drain elbow from the side of the cabinet and place it on the opposite side. Slide the unit back into the cabinet then reattach the tube using the jubilee clip (this can only be done once it is in the cabinet).
  • Page 18 / HINTS AND TIPS ABOUT YOUR NEW WATER SOFTENER 1. Please ensure that any appliances (washing machine etc.) used during ‘Economy 7’ time, do not begin their cycle between 11pm and 5am. 2. To ensure the highest efficiency is obtained, it is recommended that you top up the unit with the correct salt (Monarch’s Ultimate Tablet Salt for the Ultra HE and Premio HE or Block Salt for the Ultra HE only on a weekly basis.
  • Page 19 / MONARCH WATER DOMESTIC WATER SOFTENER WARRANTY Effective October 2021 This water softener is fully covered by a 7 year parts and 2 year labour warranty for installation within the defined sales area as determined by the Monarch distributor for your region.
  • Page 20: Service Care

    / SERVICE CARE The manufacturer of your water softener includes 55+ years of manufacturing experience, to give you a water softener that is arguably the most reliable on the market today. One of the aspects incorporated into the manufacture of your softener is ‘Prevention is better than cure’.