Starting - Atlas Copco G 2 Instruction Book

Oil-injected rotary screw compressors
Hide thumbs Also See for G 2:
Table of Contents

Advertisement

Instruction book
Step
1
2
5.2

Starting

2920 7199 10
Action
Check that all bodywork panels are fitted.
Check that sheet (5) (explaining the procedure for checking the motor rotation direction)
is affixed to the cooling air outlet of the compressor (grating on the compressor top).
Consult
Dimension
drawings.
Switch on the voltage. Press the start button for at least 3 seconds and stop it
immediately by using the emergency button.
Check the rotation direction of the motor. If the motor rotation direction is correct, the
sheet on the top grating will be blown upwards. If the sheet remains in place, the
rotation direction is incorrect.
If the rotation direction is incorrect, switch off the voltage, open the isolating
(disconnector) switch (IG) and reverse two phases of the supply cable. Switch on the
voltage and restart the compressor.
All electrical work should be carried out by professionally qualified people.
Start and run the compressor for a few minutes. Check that the compressor is operating
normally.
Air outlet valve on air receiver
Condensate drain valve on air receiver
59