About this chapter This chapter contains important user information, descriptions of safety notices and intended use of the ReadyToProcess™ 600 columns. In this chapter Section See page About this manual Important user information ReadyToProcess 600 columns Operating Instructions 29340020 AB...
(28925644). Typographical conventions Software items are identified in the text by bold italic text. Hardware items are identified in the text by bold text. In electronic format, references in italics are clickable hyperlinks. ReadyToProcess 600 columns Operating Instructions 29340020 AB...
Intended use of ReadyToProcess 600 columns ReadyToProcess 600 columns are designed for purification of biomolecules and can be suitable for production of material for clinical phases I, II and III studies. Depending on the scale of operations, ReadyToProcess 600 can be suitable for full-scale manufac- turing as well as preclinical studies.
Page 6
Note: A note is used to indicate information that is important for trouble-free and optimal use of the product. Tip: A tip contains useful information that can improve or optimize your proce- dures. ReadyToProcess 600 columns Operating Instructions 29340020 AB...
2 Safety instructions Safety instructions About this chapter This chapter describes safety precautions and the column label and information. In this chapter Section See page Safety precautions Label ReadyToProcess 600 columns Operating Instructions 29340020 AB...
Follow local and/or national regulations for safe operation and maintenance of this product. ReadyToProcess 600 columns Operating Instructions 29340020 AB...
Page 9
At least two, but preferably three or more people are recom- mended when moving ReadyToProcess 600 columns. NOTICE ReadyToProcess 600 columns have wheels for convenient handling. Make sure to clean the columns according to local proce- dures before moving them into production areas and follow the recommendations for chemical resistance.
Page 10
If the column is run in downflow mode, the pressure relief valve or rupture disc must be placed on the outlet tube. ReadyToProcess 600 columns Operating Instructions 29340020 AB...
600 column is fully traceable to the production source. Expiry Estimated expiry date. (YYYY-MM) Id No. Identifies the individual column. The lot number and ID number ensure that the ReadyToProcess 600 column is fully traceable to the production source. Manf. Manufacturing date. (YYYY-MM) Bar code...
Page 12
2 Safety instructions 2.2 Label Label text Description The column complies with applicable European directives. ReadyToProcess 600 columns Operating Instructions 29340020 AB...
3 Column description Column description About this chapter This chapter provides a description of the ReadyToProcess 600 columns and an illus- tration of the exterior parts. In this chapter Section See page General description Chemical resistance ReadyToProcess 600 columns Operating Instructions 29340020 AB...
For detailed information about the product sizes, production, testing, sanitization, resin properties, technical data, etc. consult the ReadyToProcess Column User Manual (28925644). Exterior parts The image below shows the exterior parts of a ReadyToProcess 600 column. Part Function Column label...
Page 15
3 Column description 3.1 General description Part Function Inlet (marked Bottom Inlet) Outlet (marked Top Outlet) Top lid Protective rim Handle Bottom lid Wheel ReadyToProcess 600 columns Operating Instructions 29340020 AB...
Chemical resistance Chemical resistance external surfaces The table below shows the chemical resistance of the external surfaces of 600 mm i.d. ReadyToProcess 600 columns with exposure times up to 24 hours. Chemical resistance of 600 mm i.d. columns Concentration Ethanol...
4 Installation Installation About this chapter This chapter contains information about unpacking ReadyToProcess 600 columns and removing the packaging, and warnings before use. In this chapter Section See page Unpacking Start using the column ReadyToProcess 600 columns Operating Instructions 29340020 AB...
• If the equipment is damaged, make thorough record and contact Cytiva. Handling the column upon arrival ReadyToProcess 600 columns are delivered in a plastic bag inside a crate with sepa- rate unpacking instructions. The columns have wheels for convenient handling.
If the column is run in downflow mode, the pressure relief valve or rupture disc must be placed on the outlet tube. ReadyToProcess 600 columns Operating Instructions 29340020 AB...
5 Operation Operation About this chapter This chapter provides the information required to operate ReadyToProcess 600 column in a safe way. In this chapter Section See page Connect the column Disconnect the column prior to disposal Precautions WARNING • Never exceed the rated operating pressure of the column.
Page 21
If the column is run in downflow mode, the pressure relief valve or rupture disc must be placed on the outlet tube. ReadyToProcess 600 columns Operating Instructions 29340020 AB...
Connect the column Connecting to ÄKTA ready XL Note: Connect and run the column in upflow mode. Perform the following steps to connect ReadyToProcess 600 column to an ÄKTA ready XL system: Step Action Open the TC connection for the column bottom inlet tube. Remove the piece of welded tubing and save it for later use.
Page 23
For information about how to remove the storage solution and run the column, refer to ReadyToProcess Columns User Manual (28925644). Connecting to other systems For more information about connecting to other chromatography systems, consult the ReadyToProcess Column User Manual (28925644). ReadyToProcess 600 columns Operating Instructions 29340020 AB...
Make sure to always follow national and local regulations for handling and disposal. The columns are designed to be disposed intact as combustible material. Decontamination The column must be decontaminated before decommissioning. All local regulations must be followed with regard to scrapping the column. ReadyToProcess 600 columns Operating Instructions 29340020 AB...
6 Reference information Reference information About this chapter This chapter lists the directives and standards that are fulfilled by ReadyToProcess 600 columns. Manufacturing information The table below summarizes the required manufacturing information. Requirement Information Name and address of manufacturer Cytiva Sweden AB Björkgatan 30...