Figure 3 HP 3PAR StoreServ 7400 Controller Nodes
Node/Slot/Port Location Formats
The HP 3PAR CLI and the SSMC display the controller node FC, iSCSI, and Gigabit Ethernet port
locations in the following format: <node>:<slot>:<port>. For example:
1:1:3 = Node 1: Slot 1: Port 3
2:3:1 = Node 2: Slot 3: Port 1
Node: Valid node numbers are 0-3 depending on the number of nodes installed in your system.
When viewing a system from the rear of a cabinet, nodes are numbered 0–1 or 0–3 from
bottom to top.
Slot: Valid node slot numbers are 0–3, depending on the class of nodes installed in your
system.
HP 3PAR StoreServ 7000 Storage systems have one available slot per node for an optional
HBA. Slot 0 is assigned for onboard SAS, slot 1 is assigned for onboard FC, slot 2 is available
for the HBA, and slot 3 is assigned for the onboard GigE interface (port "RC- 1 " in
Figure 4 (page
Port: Valid node port numbers are 1, 1–2, or 1–4 depending on the slot and the type of
optional HBA.
◦
On nodes 0 and 2, ports are numbered starting with 1 and ordered from left to right.
The FC ports are ordered from top to bottom.
◦
On nodes 1 and 3, ports are numbered starting with 1 and ordered from right to left.
The FC ports are ordered from bottom to top.
Legend for Node:Slot:Port Location
To locate a specific node:slot:port, see the following legend.
12)).
Understanding Component Numbering
1 1