No.
Operation
5
• Press the "Pizza / Frozen" key.
6
• Press the "Quick / Reheat" key.
7
• Press the "Hash Browns / Fro-
zen" key.
8
• Press the key "
" on the
"Temperature Control".
9
• Press the key "
" on the
"Timer".
10
• Press the key "
" on the
"Shade Control".
11
• Press the key "
" on the
"Shade Control".
12
• Press the key "
" on the
"Temperature Control".
13
• Press the key "
" on the
"Timer".
14
• Press the key "Light".
15 After checking, press the power button to finish the test.
Working description
Display and buzzer information
• The power lamp comes on.
• The buzzer sounds once when the
key is operated.
• The "Pizza / Frozen" lamp comes
on.
• The power lamp comes on.
• The buzzer sounds once when the
key is operated.
• The "Quick / Reheat" lamp comes
on.
• The power lamp comes on.
• The buzzer sounds once when the
key is operated.
• The "Hash Browns / Frozen" lamp
comes on.
• The power lamp comes on.
• The buzzer sounds once when the
key is operated.
• The temperature lamps "250" and
"500" come on in this order repeat-
edly.
• The power lamp comes on.
• The buzzer sounds once when the
key is operated.
• "8" and "8.5" on the timer display
blink in this order repeatedly.
• The power lamp comes on.
• The buzzer sounds once when the
key is operated.
• The baked color lamps of "Light",
"Medium" and "Dark" come on one
by one in this order repeatedly.
• The power lamp comes on.
• The buzzer sounds once when the
key is operated.
• The temperature control lamp
"250" comes on.
• The temperature control lamp
won't come on.
• The temperature control lamp
"500" comes on.
• The power lamp comes on.
• The buzzer sounds once when the
key is operated.
• The Algon Heater come on.
• The power lamp comes on.
• The buzzer sounds once when the
key is operated.
• The Upper Heater and Lower
Heater come on.
• The power lamp comes on.
• The buzzer sounds once when the
key is operated.
• The "Light" lamp comes on.
11
Items to be checked
Action
• The thermistor temperature is
41 -104°F
• The thermistor temperature is
106 - 120°F
• The thermistor temperature is
122°F or higher.
• The Algon Heater power ON in
during for 25 seconds.
• 214°C power OFF.
• The Upper Heater and Lower
Heater power ON in during for
25 seconds.
• 214°C power OFF.
* Check the Algon Heater's wiring
in this step.
• When power is supplied to the
Algon Heater for 5 sec.
• The oven inside becomes
bright.