Follow these steps to disconnect a SCALANCE XCM-300 and a SCALANCE LPE:
1. Disconnect the SCALANCE XCM-300 from the power supply.
2. Release the locking device using a screwdriver
The two devices are separated from each other.
3. Pull the two devices apart in a straight line until the two centering pins
of the openings
4. Close the function extender interface on the basic device and the connector on the
SCALANCE LPE with the corresponding covers.
5.9

Inserting and removing pluggable transceivers

5.9.1

General notes for SFP transceivers

Use only approved SFP transceivers
If you use SFP transceivers that have not been approved by Siemens AG, there is no guarantee
that the device will function according to its specifications.
If you use unapproved SFP transceivers, this can lead to the following problems:
• Damage to the device
• Loss of the approvals
• Violation of the EMC regulations
Use only approved pluggable transceivers.
Note
Plugging and pulling during operation
You can plug and pull pluggable transceivers with the device in operation.
Documentation for SFP transceivers
You will find detailed information in the operating instructions of the pluggable transceivers, see
the chapter "Introduction (Page 7)" section "Additional documentation".
5.9.2

Inserting a plug-in transceiver (SFP/SFP+)

Follow the steps below to insert a pluggable transceiver:
1. Remove the sealing plug of the pluggable transceiver slot.
2. Close the clip of the pluggable transceiver.
SCALANCE XCH-300/XCM-300
Equipment Manual, 10/2022, C79000-G8976-C585-02
.
WARNING
5.9 Inserting and removing pluggable transceivers
.
installing and removing
are completely out
51