Summary of Contents for Antunes Miracle Steamer MS-250

  • Page 1 ® Miracle Steamer Model MS-250/255 Owner’s Manual Manufacturing Numbers: 9100430, 9100431, 9100435, 9100436, 9100437, 9100438, 9100460, 9100462, 9100466, 9100467, 9100468, 9100933, 9100936 Original Instructions P/N 1010455 Rev. K 10/20 www.antunes.com...
  • Page 2: Table Of Contents

    In Case of Damage ......2 the installation or operation of your unit, tals and in commercial enterprises such Website ..........2 contact Antunes Technical Service at +1- as bakeries, butcheries, etc., But not for Service/Technical Assistance....2 877-392-7854 (toll free).
  • Page 3: Safety Information

    Do not immerse the cord, performed by qualified personnel Inc. (BOCA) and the Food Service unit, or plug in water. ONLY. Contact Antunes Technical Sanitation Manual of the Food y Keep the cord away from Service for adjustment or repair.
  • Page 4: Specifications

    Specifications Dimensions 17-1/8” 20-3/4” (435 mm) (527 mm) 9-1/2” (234 mm) Electrical Ratings Model & Plug Volts Watts Amps Hertz Mfg. No. Description MS-250 6-20P, 20 Amp., 250 3300 15.9 50/60 9100430 VAC, Non Locking MS-250 IEC-309 9100431 16 Amp., 250 VAC 3300 14.4 50/60...
  • Page 5: Installation

    Drawer Assembly (MS-255 only) Spatula Spatula Liner NOTE: If any parts are missing or damaged, contact Figure 1. Washing Parts–MS-250 Only Antunes Customer Service IMMEDIATELY at +1-877-392- 7856 (toll free) Drawer Remove all packing materials and protective Drip Pan coverings from the unit.
  • Page 6: Electrical

    Electrical Plumbing Turn the water valve on. Hold the Quick Disconnect Insert Place the unit on a sturdy, level table NOTE: Miracle Steamer models are over a bucket, then press and hold or other work surface. designed to use cold tap water. the white plastic tip until there’s a Distilled water may be used Ensure that the line voltage corre-...
  • Page 7: Operation

    Operation NOTE: 208V and 220/240V Miracle Ready Light Steamers are factory Turn the power on and allow the unit programmed for the following to preheat for approximately 20–30 recommended settings: READY minutes. y Total Cycle Time (CYC) = 15 Message NOTE: Do NOT push any button min., 00 secs.
  • Page 8: Hi-Limit Reset Button

    “ERR” fault located on the rear of the unit (Figure 7). proximately 1 second. code. If the unit requires continuous resetting, contact Antunes Technical Service. NOTE: It is recommended that the Fault Codes SHO and H2O settings be...
  • Page 9: Maintenance

    Maintenance Daily MS-250: Remove the Spatula, Reinstall the Steam Vent first, fol- NOTE: Frequency of cleaning is de- Spatula Liner, Drip Pan, Top Cover, lowed by the remaining items. termined by water conditions, and Steam Vent (Figure 9). usage, and water filtration NOTE: Failure to properly clean and systems.
  • Page 10: Monthly

    Monthly The Miracle Steamer utilizes an open NOTE: To ensure proper steaming Seasoning mixture consists of 3/4 ounces steam Generator. Water sprayed onto characteristics, some calcium/ (25ml/ 25cc) baking soda and 1 quart the Generator surface flashes into steam mineral deposits must be (950ml/950cc) of water.
  • Page 11 Mesh O-ring Screen Tubing Male Quick Strainer Disconnect Insert Figure 12. Inlet Hose Assembly Checking and Cleaning the Water Strainer The Water Strainer protects your equip- ment from any foreign debris in the water line that could get into the food or damage the unit’s solenoid and cause the unit to leak or flood.
  • Page 12: Troubleshooting

    Unit does not heat up (Control Display is manual. If the Hi-Limit Thermostat on). requires continuous resetting, contact Control Board is inoperable. your maintenance person or Antunes Steam Generator is inoperable. Technical Service. Loose, burnt, or broken wires in circuit.
  • Page 13 Unit floods overnight unit and test. If a leak is still present, replace the Solenoid and/or continues to Valve. Contact your maintenance person or Antunes steam even when in idle Technical Service. mode. Solenoid Valve is installed If the Solenoid Valve was replaced, verify that the “IN”...
  • Page 14: Replacement Parts

    Note 306P101* Nut, Hex, #6-32 306P105* Screw, Machine, #6-32 x 1/2” Use only genuine Antunes replacement parts in this unit. Use of parts other than those supplied by the manufacturer 306P123* Screw, Machine, #6-32 x 7/8” will void the warranty.
  • Page 15: Exploded Views

    Exploded Views Exploded Diagram 1 P/N 1010455 Rev. K 10/20 ®...
  • Page 16: Exploded Diagram 2

    Exploded Views Exploded Diagram 2 P/N 1010455 Rev. K 10/20 ®...
  • Page 17: Exploded Diagram 3

    Exploded Views Exploded Diagram 3 Dual Water Pressure Regulator Kit - Part No. 7000235 Item Part # Description Qty. (All units except Mfg. No. 9100933) 7000139 Elbow, Quick Disconnect - 1/4” To Steamer To Steamer 2030126 Tubing 1/4” I.D. PVC BRD. 24” Long 2030125 Tubing 1/4”...
  • Page 18: Wiring Diagram

    Wiring Diagram *NOTE: For 208-240 VAC units, the two primary coils are wired in series with one another. For 120 VAC units, the two primary coils are wired in parallel with one another. P/N 1010455 Rev. K 10/20 ®...
  • Page 19: Notes

    Notes P/N 1010455 Rev. K 10/20 ®...
  • Page 20 Travel Time & Mileage in excess of 2 hours (100 miles/160 km) round trip from the nearest authorized service agency. Antunes reserves the right to make changes in design or add any improvements on any product. The right is always reserved to modify equipment because of factors beyond our control and government regulations.