Antunes Egg Station Dual Zone ESDZ-1200 Series Owner's Manual
Hide thumbs Also See for Egg Station Dual Zone ESDZ-1200 Series:

Advertisement

Quick Links

Egg Station Dual Zone
Model ESDZ-1200
owner's manual
Manufacturing Numbers:
9300636, 9300640, and 9300654
www.antunes.com
P/N 1011450 Rev. F 05/18

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Egg Station Dual Zone ESDZ-1200 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Antunes Egg Station Dual Zone ESDZ-1200 Series

  • Page 1 Egg Station Dual Zone Model ESDZ-1200 owner’s manual Manufacturing Numbers: 9300636, 9300640, and 9300654 www.antunes.com P/N 1011450 Rev. F 05/18...
  • Page 2: Table Of Contents

    Error Codes .............12 Service/Technical Assistance Hi Limit Control ............12 Factory Reset ............12 If you experience any problems with the installation or operation of your unit, contact Antunes Technical Service at Replacement Parts ...........13 +1-877-392-7854 (toll free Wiring Diagram ............16 Limited Warranty ............20 Fill in the information below and have it handy when calling Antunes Technical Service for assistance.
  • Page 3: Important Safety Information

    IMPORTANT Antunes reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, addi- tions, or replacements for previously purchased equipment.
  • Page 4: Specifications

    EGG STATION DUAL ZONE SPECIFICATIONS Dimensions Electrical Ratings Model & Volts Watts Hertz Mfg. Nos. ESDZ-1200 9300636 200-240~ 3000 15/12.5 50/60 9300640 9300654 Electrical Cord & Plug Configurations Model & Description Configuration Mfg. Nos. ESDZ-1200 IEC-309 16 Amp., 9300636 220-250 VAC, 3 Pin 9300654 CEE 7/7 ESDZ-1200...
  • Page 5: Installation

    Unpacking 1. Remove unit and all packing materials from shipping carton. NOTE: If any parts are missing or damaged, con- tact Antunes Customer Service IMMEDIATELY at +1-877-392-7856 (toll free). 2. Remove information packet. 3. Remove all packing materials and protective coverings from the unit.
  • Page 6: Operation

    Grill Surface. ROUND FOLDED TIME 3 TIME 4 4. Ensure that the Egg Racks and Top Covers are in A. J. ANTUNES & CO the down position during warm-up and when not Front Display Program Down Arrow loading or removing eggs.
  • Page 7: Egg Cooking Procedure

    EGG STATION DUAL ZONE OPERATION (continued) Egg Cooking Procedure NOTE: When possible, eggs should be pulled from the cooler and not kept at the grill. Tempering 1. Ensure that the unit is set on a level surface. eggs increases their temperature. Egg kept past 30 minutes will result in a higher proportion of over- 2.
  • Page 8: Best Practices

    EGG STATION DUAL ZONE BEST PRACTICES Troubleshooting for Under Cooked Eggs Troubleshooting Eggs leaking out of Egg Rings 1. Level the egg station. (See “Leveling the Unit” on page 5) Egg Ring Replacement depends on usage but in gen- eral, Egg Rings should be replaced yearly. If eggs begin 2.
  • Page 9: Programming

    EGG STATION DUAL ZONE PROGRAMMING Factory Default Cooking Times 2. The unit enters manager mode at the Adjust Timers option. Press the desired timer to change The factory default cooking times are listed below per and use the Up and Down arrow buttons to button name: change the time as desired.
  • Page 10: Maintenance

    EGG STATION DUAL ZONE MAINTENANCE WARNING CAUTION Turn the power off and allow the unit to cool Chlorides or high levels of pH or phosphates before performing any service or maintenance. in cleaning agents (e.g. bleach, sanitizers, degreasers, or detergents) could cause permanent Daily Cleaning damage to stainless steel and aluminum surfaces.
  • Page 11: Troubleshooting

    Do not use an abrasive scrubbing pad to clean Egg Rings. Damaged Egg Ring. Replace Egg Ring. If the troubleshooting steps listed do not solve your problem, contact Antunes Technical Service at +1-877-392-7854 (toll free). P/N 1011450 Rev. F 05/18...
  • Page 12: Error Codes

    (toll free) for assis- NOTE: If the Hi Limit Controls require continuous reset- Rear heat is too low, or not tance. ting, contact Antunes Technical Service at +1-877-392- reaching setpoint tempera- 7854 (toll free) or at 630-784-1000. ture within 30 minutes.
  • Page 13: Replacement Parts

    EGG STATION DUAL ZONE REPLACEMENT PARTS (Order (Order Item 91) Item 91) Do NOT plug any personal or unauthorized USB device into the USB port of this unit. Doing so may cause damage to the unit. See Next Page P/N 1011450 Rev. F 05/18...
  • Page 14 EGG STATION DUAL ZONE REPLACEMENT PARTS (continued) (Order item 101) P/N 1011450 Rev. F 05/18...
  • Page 15 EGG STATION DUAL ZONE REPLACEMENT PARTS (continued) Item Part Description Qty. Item Part Description Qty. 0200367 Gasket, Platen Seam 0400481 Cover, Contactor 0507598 Cover, Platen Seam 0400484 Cover, Ele. Insulation 306P146* Washer #6 Nylon .062 THK 0507657 Spacer, “ L” Bracket 7001017 Contactor Kit 2120268...
  • Page 16: Wiring Diagram

    EGG STATION DUAL ZONE WIRING DIAGRAM P/N 1011450 Rev. F 05/18...
  • Page 17 EGG STATION DUAL ZONE NOTES P/N 1011450 Rev. F 05/18...
  • Page 18 EGG STATION DUAL ZONE NOTES P/N 1011450 Rev. F 05/18...
  • Page 19 EGG STATION DUAL ZONE NOTES P/N 1011450 Rev. F 05/18...
  • Page 20: Limited Warranty

    (100 miles/160 km) round trip from the nearest authorized service agency. 2. Antunes reserves the right to make changes in design or add any improvements on any product. The right is always reserved to modify equipment because of factors beyond our control and government regulations. Changes to update equipment do not constitute a warranty charge.

This manual is also suitable for:

930063693006409300654Esdz-1200

Table of Contents