Advertisement

Quick Links

®
Steam and Hold
Infini Steam
IS-8000
Owner's Manual
Mfg. Number:
9100948
Original Instructions
P/N 1011582 Rev. F 07/21
CAUTION: Read all instructions before using the unit.
www.antunes.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IS-8000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Antunes IS-8000

  • Page 1 ® Steam and Hold Infini Steam IS-8000 Owner’s Manual Mfg. Number: 9100948 Original Instructions P/N 1011582 Rev. F 07/21 CAUTION: Read all instructions before using the unit. www.antunes.com...
  • Page 2: Table Of Contents

    But not Service/Technical Assistance problems with the installation or operation for continuous mass production of food. of this product contact Antunes Customer In Case of Damage Service immediately at +1-877-392-7856 Equipment Information to Save (toll free).
  • Page 3: Safety Information

    Install this unit to comply with the performed by qualified personnel y Do not block or cover any basic plumbing code of the Building ONLY. Contact Antunes Technical openings on the equipment. Officials and Code Administrators, Service for adjustment or repair.
  • Page 4: Specifications

    Specifications Electrical Ratings Water Requirements Water Quality (Treated Water): Model & Volts Watts Hertz Mfg. No. Hardness (Calcium & Magnesium) 1 GPG Maximum 9100948 9000 50/60 Total Alkalinity 600 PPM Maximum 9100949 Total Silica 150 PPM Maximum Iron Content 0.1 PPM Maximum Electrical Cord &...
  • Page 5: Unpacking

    Space for this is provided on page 2. NOTE: If any parts are missing or damaged, contact Antunes IMMEDIATELY at 1-800-253-2991 (toll free in the U.S. and Canada) or at 630-784-1000. 4. Wash all removable components in soap and water.
  • Page 6: Installation

    The steamer must be level front-to-back or pitched slightly backwards for the cavities to drain Antunes Recommended Clearances from walls and other Equipment properly. Rear of Left Side of...
  • Page 7: Supply Wiring

    Operations Supply Wiring Initial Startup WARNING Grounding Connect the water treatment system ELECTRICAL SHOCK HAZARD Stud to the treated water inlet according to Disconnect power before servicing. Figure 3 on page 6. Replace all parts and panels before operating. Failure to do so can result in Plug the power cord into the appropriate outlet.
  • Page 8: System Power-Up

    System Power-up On the display, press the appropriate Tap the button for the primed timer. Upon application of power, the system button for the drawer being used. There are three options: Start the will display the following splash timer, Delete the timer (trash), or screen.
  • Page 9: Steamer Settings

    Edit Wakeup which the Steamer turns Diagnostics Diagnostics displays the items that the unit This option works with is constantly measuring. This cannot be the Antunes RO system. edited. Please see your RO Period Clean Boiler manual for information Edit Options...
  • Page 10: Reset To Factory Defaults

    Maintenance Reset to Factory Defaults IMPORTANT Daily Resetting the Steam and Hold to Factor Wash, rinse, and sanitize the drip The Steam and Hold requires a trays at the sink. Allow to air dry. Defaults erases all edits, menu changes, minimal amount of maintenance.
  • Page 11: Weekly

    Failure to properly clean and The following screen appears and begins the cleaning cycle. de-scale boiler will cause significant changes in operation CLEANING of steamer. Antunes is not Clean Fill responsible for any damage or Temp 119 complications due to negligent Hi Probe DRY Lo Probe DRY maintenance of steamer.
  • Page 12 Weekly Maintanence - Cleaning Cycle WARNING Failure to properly follow the cleaning instructions for the unit will result in excess buildup of scale and lime as seen in the examples below. Excess buildup of scale and lime may cause damage to the unit and will void the warranty.
  • Page 13: Error Messages

    CAUTION Use of any replacement part other than those supplied by Antunes of their authorized distributors can cause injury to the operator and damage to the equipment and will void all warranties.
  • Page 14: Troubleshooting

    Troubleshooting Your Antunes Steamer is designed to operate smoothly and efficiently if properly maintained. However, the following is a list of checks or activities to make in the event of a problem: Problem Possible Cause Services Corrective Action Steamer Cavity Drain Screen is User Remove both drawers of steamer and clean Drain Screens.
  • Page 15: Wiring Diagram

    Wiring Diagram N.O. N.C. P/N 1011582 Rev. F 07/21 ®...
  • Page 16: Exploded Diagram #1

    Exploded Diagram #1 Item 15 Mfg. No. 9100949 ONLY Item 4 P/N 1011582 Rev. F 07/21 ®...
  • Page 17: Exploded Diagram #2

    Exploded Diagram #2 Item 7 Item 208 P/N 1011582 Rev. F 07/21 ®...
  • Page 18: Exploded Diagram #3

    Exploded Diagram #3 P/N 1011582 Rev. F 07/21 ®...
  • Page 19: Exploded Diagram #4

    Exploded Diagram #4 P/N 1011582 Rev. F 07/21 ®...
  • Page 20: Photo Diagram

    Photo Diagram Water Level Board Power Supply Board Display Board Circuit Breaker Main Control Board Heat sync Power Button Board SSR Relay Pressure Release Switch Boiler Figure 11. Interior Side Panel View Regulator Cavity Breakout Assembly Board Solenoid Drain Tubing System Drain Treated Water Intake...
  • Page 21: Replacement Parts

    Control Panel NOTICE 0510979 Front Plate 7002357 Drip Pan Kit Use only genuine Antunes replacement parts in this unit. Use 0511265 Clean Cycle Mt Brkt of parts other than those supplied by the manufacturer will void 0511272 Electrical Mount Bracket the warranty.
  • Page 22: Replacement Parts Continued

    Replacement Parts Continued Item No. Part # Description Qty. Item No. Part # Description Qty. 2110223 4050180 Heat Sink 2120174 Spacer, #10, 5/15 Od X 3/16 Lg 4050236 Contactor, 2 Pole Normally Open Spacer, .115 Id X .25 Od .062 , 4051010 Relay, Random Phase, Solid State 2120249...
  • Page 23: Notes

    Notes P/N 1011582 Rev. F 07/21 ®...
  • Page 24 Travel Time & Mileage in excess of 2 hours (100 miles/160 km) round trip from the nearest authorized service agency. Antunes reserves the right to make changes in design or add any improvements on any product. The right is always reserved to modify equipment because of factors beyond our control and government regulations.

Table of Contents