® ESDZ-1200 Scan with mobile device or enter URL for product and service information. http://tiny.cc/ajaESDZ Egg Station Dual Zone Model ESDZ-1200 Owner’s Manual Manufacturing Number 9300624, 9300625, 9300635 CAUTION: Read all instructions before using the unit. Original Instructions This manual is for the exclusive use of licensees and employees of McDon- ald’s Systems, Inc..
But not for continuous Service/Technical Assistance....2 problems with the installation or operation mass production of food. of this product contact Antunes Customer In Case of Damage ........ 2 Service immediately at +1-877-392-7856 Equipment Information to Save ....2 (toll free).
Inc. (BOCA) and the Food Service performed by qualified personnel Sanitation Manual of the Food y Do not block or cover any ONLY. Contact Antunes Technical and Drug Administration (FDA). openings on the equipment. Service for adjustment or repair. y Install and locate the equipment...
Unpacking Remove unit and all packing materials from shipping carton. NOTE: If any parts are missing or dam- aged, contact Antunes Cus- tomer Service IMMEDIATELY at +1-877-392-7856 (toll free). Remove information packet. Remove all packing materials and protective coverings from the unit.
Operating Instructions Rear Display Up Arrow Power and Controls Preparing Unit Button Button Place Egg Rings into Egg Racks. Vertically place the pins of the Egg Racks into the slots on the Hinge Bracket. ROUND FOLDED TIME 3 TIME 4 Check to see that all Egg Rings are seated flat on the Grill Surface.
Egg Cooking Procedure NOTE: The top row of the control panel 13. Open the appropriate Top Cover and Ensure that the unit is set on a level raise the Egg Rack about 1 inch (26 controls the REAR grill and the surface.
Best Practices Troubleshooting for Under Troubleshooting Eggs leaking Cooked Eggs out of Egg Rings Level unit - adjust feet if necessary. Egg Ring Replacement depends on usage The unit must be level before use. but in general, Egg Rings should be Before using the unit, adjust the legs replaced yearly.
Programming Manager Mode Factory Default Cooking Times To change the language between English and French, press the Down Manager mode allows access to view and The factory default cooking times are listed arrow button for French (FR-C). Press change the programming. This includes: below per button name: the Up arrow button for English (En).
Maintenance Daily Cleaning NOTE: If a scraper is needed during CAUTION cleaning, use a plastic scraper. DO NOT USE A METAL WARNING Chlorides or high levels of pH or SCRAPER. phosphates in cleaning agents (e.g. Turn the power off and allow the unit to bleach, sanitizers, degreasers, or NOTE: Do NOT Pour water onto the grill...
Do not use an abrasive scrubbing pad to clean Egg Rings. Damaged Egg Ring. Replace Egg Ring. If the troubleshooting steps listed do not solve your problem, contact Antunes Technical Service at +1-877-392-7854 (toll free) for further assistance. P/N 1011401 Rev. L 11/20 ®...
Front platen over-temperature condition. Factory Reset Hi Limit Control If required, the ESDZ-1200 can be reset The ESDZ-1200 has two Hi Limit resets - to factory defaults. Follow these steps to one for the front cooking surface and one reset the unit: for the rear cooking surface.
0200366 Gasket, Housing (Side) 7000272 Thermostat, Hi-Limit Kit NOTE Screw, Mach. Truss Head Phillips, Use only genuine Antunes replacement parts in this unit. Use of 306P180* #6-32X 1/4” replacement parts other than those supplied by the manufacturer 0507655 Bracket, Display will void the warranty.
Page 15
Replacement Parts Parts List Continued NOTE Use only genuine Antunes replacement parts in this unit. Use of replacement parts other than those supplied by the manufacturer will void the warranty. Item Part # Description Qty. 7001243 ESDZ-1200 Top Cover Kit ESDZ-1200 Top Cover &...
Replacement Parts Exploded Diagram 1 (Order Item 91) Do NOT plug any per- sonal or unauthorized USB device into the USB port of this unit. Doing so may cause damage to the unit. See Next Page P/N 1011401 Rev. L 11/20 ®...
Travel Time & Mileage in excess of 2 hours (100 miles/160 km) round trip from the nearest authorized service agency. Antunes reserves the right to make changes in design or add any improvements on any product. The right is always reserved to modify equipment because of factors beyond our control and government regulations.