IDEC HR6S-AF Original Instructions Manual page 81

Safety module
Hide thumbs Also See for HR6S-AF:
Table of Contents

Advertisement

Bit sequence
Description
0010110101
Input S12 is expected to
change its state. In the
case of a configuration
with antivalent inputs,
inputs S12 and S13 are
expected to change their
states.
0010111100
Input S22 is expected to
change its state. In the
case of a configuration
with antivalent inputs,
inputs S22 and S23 are
expected to change their
states.
0010101011
Waiting for startup test.
0010101010
Waiting for rising edge
for automatic/manual
start or monitored start.
0010101110
Start input activated.
Waiting for falling edge
for monitored start.
0010101111
Device in operating state
Run:Outputs Energized,
safety-related outputs
activated.
(1) Type of message: E = Error detected, A = Alert, S = Status information
HR9Z-B2192 8/2020
Correctives
-
-
-
-
-
-
Diagnostics
(1)
Type
S
S
S
S
S
S
81