Mechanical Installation

Mounting to DIN Rail
The device can be mounted to the following DIN rails as per IEC 60715:
35 x 15 mm (1.38 x 0.59 in)
35 x 7.5 mm (1.38 x 0.29 in)
Mounting procedure (left illustration)
Step
Action
1
Slightly tilt the device and hook it onto the DIN rail.
2
Push the lower part of the device towards the DIN rail.
3
Snap in the DIN rail clip.
Dismounting procedure (center illustration)
Step
Action
1
Unlock the DIN rail clip using a screwdriver.
2
Pull the lower part of the device away from the DIN rail and lift the device towards the top to
remove it from the DIN rail.
HR9Z-B2192 8/2020
mm
15
in.
0.59
1
0.04
Installation
7.5
0.29
1
0.04