Application Function 1
Characteristic
Typical applications
Type of outputs of sensor/device providing the input signal
for application function
S## terminals to be connected
Dynamization
Signal interlock monitoring
Synchronization of safety-related inputs
Wiring of the inputs for Emergency Stop
Wiring of the inputs for guards
HR9Z-B2192 8/2020
Value/Description
Monitoring of Emergency Stop circuits as per
ISO 13850 and IEC 60204-1, stop category 0
Monitoring of guards as per ISO 14119/14120
with electrical switches
Normally open, normally closed and/or changeover
outputs
S11-S12 and S21-S22
Yes
Between terminals S12 and S22
No
Functions
59