IDEC HR6S-AF Original Instructions Manual page 61

Safety module
Hide thumbs Also See for HR6S-AF:
Table of Contents

Advertisement

Application Function 3
Characteristic
Typical applications
Type of outputs of sensor/device providing the input signal
for application function
S## terminals to be connected
Dynamization
Signal interlock monitoring
Synchronization:
Synchronized terminals
S12 synchronized with S22
Wiring of the inputs for coded magnetic switches
HR9Z-B2192 8/2020
Value/Description
Monitoring of guards as per ISO 14119/14120
with electrical switches
Monitoring of guards as per ISO 14119/14120
with coded magnetic switches
Monitoring of proximity switches
Normally open, normally closed and/or changeover
outputs
S11-S12 and S21-S22
Yes
No
Synchronization time
S12 and S22 have to be activated within 0.5 s.
Functions
61

Advertisement