IDEC HR6S-AF Original Instructions Manual page 64

Safety module
Hide thumbs Also See for HR6S-AF:
Table of Contents

Advertisement

Functions
Application Function 6
Characteristic
Typical applications
Type of outputs of sensor/device providing the input signal
for application function
S## terminals to be connected
Dynamization
Signal interlock monitoring
Synchronization:
Synchronized terminals
S12 synchronized with S22
Wiring of the inputs for sensors/devices with OSSD outputs
64
Value/Description
Monitoring of electro-sensitive protective
equipment such as type 4 light curtains as per
IEC 61496-1
Monitoring of RFID sensors
OSSD (Output Signal Switching Device) outputs
S12 and S22
No
Between terminals S12 and S22
Synchronization time
S12 and S22 have to be activated within 0.5 s.
HR9Z-B2192 8/2020

Advertisement

Table of Contents
loading

Table of Contents