The rear of the main unit Name Identification plate Reset button USB port ATTENTION Sensitive sensor plate The white sensor surface consists of a thin ceramic plate. This plate may be destroyed by mechanical pressure! ► Take care of the sensitive sensor surface during cleaning! Page 3...
PMSA Operating Manual Table of contents Your PSMA at a glance ����������������������������������������������������������������� 2 The main unit ......................2 The rear of the main unit ..................3 1� Introduction �������������������������������������������������������������������� 6 Information about this operating manual ..........6 Limitation of liability ................6 Symbols used in this manual ..............
Page 5
Exporting measurements ............... 18 Configuring the device ������������������������������������������������� 19 Sensor settings ..................19 8.1.1 Deactivating the "Measurement Valid" window ........19 8.1.2 Updating the PMSA Firmware ............... 19 8.1.3 Entering the Admin password ............... 20 Product types ..................20 Selecting a language ................21 9�...
Introduction Information about this operating manual This operating manual is designed to enable you to use the PMSA safely and effec- tively. It is part of the device, has to be stored nearby and must be easily accessible to users at all times.
PMSA Operating Manual For your safety The device complies with the following European directives: • Restriction of Hazardous Substances in Electrical and Electronic Equipment (RoHS) • Electromagnetic compatibility (EMC) The device corresponds to state-of-the-art technology. However, it is still associated with a number of residual hazards.
General safety information Follow the safety instructions below to avoid personal injury and material damage: • If you notice loose parts or damage on the device contact your distributor. All of the device’s technical features have been inspected and tested before delivery. Every device has a serial number.
PMSA Operating Manual On receipt of your device Taking the device out of its packaging • Take the device out of its packaging. • Next, make sure that it is not damaged and that no parts are missing. ATTENTION Sensitive sensor plate The white sensor surface consists of a thin ceramic plate.
After successful installation exit the installation wizard with Finish (figure 2). Setting up the device • Insert the USB Mini B connector into the PMSA (figure 3). • Insert the USB connector into the computer. » The required driver was installed with the evaluation software in the previous step and should now be ready for use.
"Settings" button (figure 4) Select the COM interface of the PMSA from the drop-down menu. After selecting the COM interface, the con- nection to the PMSA can be tested via the "Test" button. » After successful completion of the test, a message appears and the LED bar of the device lights up blue.
Page 13
After successful completion of the blank mea- surement, the progress window opens again (figure 9). Now place the paper to be measured in the device and close the lid (figure 10). Continue the measurement process by clicking the "OK" button Now the device performs the measurement. »...
PMSA Operating Manual Product types Grammage Product type Paper type [g/m²] *Reference ! Only used for testing the moisture meter ! Carbonless paper CFB 60 60 g/m² Fluting 100 100 g/m² Fluting 110 110 g/m² Fluting 127 127 g/m² Fluting 140 140 g/m²...
Selecting the product type Due to the wide range of different types of papers in use, there are no default product type categories. For the different product types of the PMSA, the grammage of the paper sheet and the paper type are decisive.
PMSA Operating Manual Database / Archive In the database all stored measuring values can be displayed. Each stored measurement has its own identification number. Filter To facilitate the search, filters can be applied to the stored measurements in the data- base.
In the second field enter the end date of the desired time period (figure 15). » By default, the current date is selected as the end date. » The end date can be chosen on the calendar or entered manually in the format (TT-MM-JJJJ).
PMSA Operating Manual Additional database functions All data from the database can be deleted, further processed or exported. 7.2.1 Deleting measurements • Mark the desired measurement series by clicking on the empty field in front of the "ID" column. »...
The file „pmsa.log“ can be usually found in your public documents folder: » "C:\Users\Public\Documents\Schaller Messtechnik GmbH\PMSA\log" • If necessary, you will receive a new file from Schaller Messtechnik GmbH, which is matched to the serial number of your PMSA. »...
» The update process can take up to 2 minutes. After the update has been completed your PMSA device is ready for use again. If an "Error" message appears on the display (figure 20), please check whether the correct COM Port is set (see 4.3 Setting the COM...
Selecting a language • Open the language settings by clicking on the "Language" button Cleaning and maintenance Regularly cleaning and maintaining the device will ensure that it will have a long service life and stay in good condition. Resetting the hardware/device If the device has stopped operating for some reason, the hardware/device can be reset.
PMSA Operating Manual Cleaning the device ATTENTION Do not clean with fluids Water or cleaning fluid getting inside the device can destroy the device. ► Only clean with dry materials. ATTENTION Sensitive sensor plate The white sensor surface consists of a thin ceramic plate. This can be destroyed by mechanical pressure! ►...
10. Faults If the measures listed below fail to remedy any faults or if the device has faults not listed here, please contact Schaller Messtechnik GmbH. Fault Cause Remedy Measuring error The temperature of the ma- The temperature of the...
PMSA Operating Manual 11. Storage and disposal 11.1 Storing the device The device must be stored as follows: • Do not store outdoors • Store in a dry and dust-free place • Protect the device from sunlight • Avoid mechanical shocks/loads •...
12. Device information 12.1 EC declaration of conformity _______________ KONFORMITÄTSERKLÄRUNG DECLARATION OF CONFORMITY Name/ Adresse des Herstellers: Schaller Messtechnik GmbH Max-Schaller-Straße 99 Name/ address of manufacturer: A – 8181 St. Ruprecht Produktbezeichnung: Schaller Product designation: Typenbezeichnung: PMSA Type designation: Produktbeschreibung: Messgerät zur Bestimmung des Wassergehalts in Papier...
Page 26
PMSA Operating Manual Für das angeführte Produkt ist eine vollständige Dokumentation mit Betriebsanleitung in Originalfassung vorhanden. For the mentioned product a complete documentation with manual of instruction in original version is available. Bei Änderungen, die nicht vom Hersteller spezifiziert sind, verliert diese Konformitätserklärung die Gültigkeit.
Page 27
_______________ DECLARATION OF CONFORMITY Schaller Messtechnik GmbH Name/ address of manufacturer: Max-Schaller-Straße 99 A – 8181 St. Ruprecht Product designation: Schaller PMSA Type designation: Product description: Measuring instrument for determining the water content in paper The designated product is in conformity with the following directives: Electromagnetic Compatibility Regulations 2016 Great Britain •...
Page 28
PMSA Operating Manual For the mentioned product, a complete documentation with manual of instruction in original version is available. In case of any changes not agreed upon with the manufacturer, this declaration of conformity loses its validity. St. Ruprecht a.d. Raab, 31.07.2022 …............
12.2 Technical data Measuring range 1 % to 20 % moisture content (product type dependant) Resolution of the measure- 0.01 % moisture content ment 0.1 °C / 0.3 °F temperature Operating temperature +10 °C to +40 °C Storage temperature -20 °C to +60 °C Temperature compensation automatic Paper sheet size...