Moisture meter
Hide thumbs Also See for PMSA:

Advertisement

Quick Links

Moisture meter
Operating Manual
PMSA
Single paper sheet moisture analyser
for measuring the moisture content of a single sheet
of paper
78,0 °F | 6,16 % | 456 kg/m
| -27,3 td | 0,64 aw | 51,9 %r.H. | 14,8 % abs | 100,4 g/m
| 09 m/s | 4,90 Ugl | 1
3
2
Always read this operating manual before using the PMSA!
Version 2.1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PMSA and is the answer not in the manual?

Questions and answers

Summary of Contents for Schaller PMSA

  • Page 1 78,0 °F | 6,16 % | 456 kg/m | -27,3 td | 0,64 aw | 51,9 %r.H. | 14,8 % abs | 100,4 g/m | 09 m/s | 4,90 Ugl | 1 Always read this operating manual before using the PMSA! Version 2.1...
  • Page 2: Your Psma At A Glance

    PMSA Operating Manual Your PSMA at a glance The main unit Name Lid push button Sensor plate LED status bar IR temperature sensor Page 2...
  • Page 3: The Rear Of The Main Unit

    The rear of the main unit Name Identification plate Reset button USB port ATTENTION Sensitive sensor plate The white sensor surface consists of a thin ceramic plate. This plate may be destroyed by mechanical pressure! ► Take care of the sensitive sensor surface during cleaning! Page 3...
  • Page 4: Table Of Contents

    PMSA Operating Manual Table of contents Your PSMA at a glance ����������������������������������������������������������������� 2 The main unit ......................2 The rear of the main unit ..................3 1� Introduction �������������������������������������������������������������������� 6 Information about this operating manual ..........6 Limitation of liability ................6 Symbols used in this manual ..............
  • Page 5 Exporting measurements ............... 18 Configuring the device ������������������������������������������������� 19 Sensor settings ..................19 8.1.1 Deactivating the "Measurement Valid" window ........19 8.1.2 Updating the PMSA Firmware ............... 19 8.1.3 Entering the Admin password ............... 20 Product types ..................20 Selecting a language ................21 9�...
  • Page 6: Introduction

    Introduction Information about this operating manual This operating manual is designed to enable you to use the PMSA safely and effec- tively. It is part of the device, has to be stored nearby and must be easily accessible to users at all times.
  • Page 7: Symbols Used In This Manual

    For technical advice, please contact our customer service department at: Schaller Messtechnik GmbH Max-Schaller-Straße 99 A - 8181 St.Ruprecht an der Raab Telephone: +43 (0)3178 28899 Fax: +43 (0)3178 28899 - 901 E-Mail: info@humimeter.com Internet: www.humimeter.com © Schaller Messtechnik GmbH 2022 Page 7...
  • Page 8: For Your Safety

    PMSA Operating Manual For your safety The device complies with the following European directives: • Restriction of Hazardous Substances in Electrical and Electronic Equipment (RoHS) • Electromagnetic compatibility (EMC) The device corresponds to state-of-the-art technology. However, it is still associated with a number of residual hazards.
  • Page 9: General Safety Information

    General safety information Follow the safety instructions below to avoid personal injury and material damage: • If you notice loose parts or damage on the device contact your distributor. All of the device’s technical features have been inspected and tested before delivery. Every device has a serial number.
  • Page 10: On Receipt Of Your Device

    PMSA Operating Manual On receipt of your device Taking the device out of its packaging • Take the device out of its packaging. • Next, make sure that it is not damaged and that no parts are missing. ATTENTION Sensitive sensor plate The white sensor surface consists of a thin ceramic plate.
  • Page 11: Setting Up

    After successful installation exit the installation wizard with Finish (figure 2). Setting up the device • Insert the USB Mini B connector into the PMSA (figure 3). • Insert the USB connector into the computer. » The required driver was installed with the evaluation software in the previous step and should now be ready for use.
  • Page 12: Setting The Com Port

    "Settings" button (figure 4) Select the COM interface of the PMSA from the drop-down menu. After selecting the COM interface, the con- nection to the PMSA can be tested via the "Test" button. » After successful completion of the test, a message appears and the LED bar of the device lights up blue.
  • Page 13 After successful completion of the blank mea- surement, the progress window opens again (figure 9). Now place the paper to be measured in the device and close the lid (figure 10). Continue the measurement process by clicking the "OK" button Now the device performs the measurement. »...
  • Page 14: Product Types

    PMSA Operating Manual Product types Grammage Product type Paper type [g/m²] *Reference ! Only used for testing the moisture meter ! Carbonless paper CFB 60 60 g/m² Fluting 100 100 g/m² Fluting 110 110 g/m² Fluting 127 127 g/m² Fluting 140 140 g/m²...
  • Page 15: Selecting The Product Type

    Selecting the product type Due to the wide range of different types of papers in use, there are no default product type categories. For the different product types of the PMSA, the grammage of the paper sheet and the paper type are decisive.
  • Page 16: Database / Archive

    PMSA Operating Manual Database / Archive In the database all stored measuring values can be displayed. Each stored measurement has its own identification number. Filter To facilitate the search, filters can be applied to the stored measurements in the data- base.
  • Page 17: Filter By Keyword

    In the second field enter the end date of the desired time period (figure 15). » By default, the current date is selected as the end date. » The end date can be chosen on the calendar or entered manually in the format (TT-MM-JJJJ).
  • Page 18: Additional Database Functions

    PMSA Operating Manual Additional database functions All data from the database can be deleted, further processed or exported. 7.2.1 Deleting measurements • Mark the desired measurement series by clicking on the empty field in front of the "ID" column. »...
  • Page 19: Configuring The Device

    The file „pmsa.log“ can be usually found in your public documents folder: » "C:\Users\Public\Documents\Schaller Messtechnik GmbH\PMSA\log" • If necessary, you will receive a new file from Schaller Messtechnik GmbH, which is matched to the serial number of your PMSA. »...
  • Page 20: Entering The Admin Password

    » The update process can take up to 2 minutes. After the update has been completed your PMSA device is ready for use again. If an "Error" message appears on the display (figure 20), please check whether the correct COM Port is set (see 4.3 Setting the COM...
  • Page 21: Selecting A Language

    Selecting a language • Open the language settings by clicking on the "Language" button Cleaning and maintenance Regularly cleaning and maintaining the device will ensure that it will have a long service life and stay in good condition. Resetting the hardware/device If the device has stopped operating for some reason, the hardware/device can be reset.
  • Page 22: Cleaning The Device

    PMSA Operating Manual Cleaning the device ATTENTION Do not clean with fluids Water or cleaning fluid getting inside the device can destroy the device. ► Only clean with dry materials. ATTENTION Sensitive sensor plate The white sensor surface consists of a thin ceramic plate. This can be destroyed by mechanical pressure! ►...
  • Page 23: Faults

    10. Faults If the measures listed below fail to remedy any faults or if the device has faults not listed here, please contact Schaller Messtechnik GmbH. Fault Cause Remedy Measuring error The temperature of the ma- The temperature of the...
  • Page 24: Storage And Disposal

    PMSA Operating Manual 11. Storage and disposal 11.1 Storing the device The device must be stored as follows: • Do not store outdoors • Store in a dry and dust-free place • Protect the device from sunlight • Avoid mechanical shocks/loads •...
  • Page 25: Device Information

    12. Device information 12.1 EC declaration of conformity _______________ KONFORMITÄTSERKLÄRUNG DECLARATION OF CONFORMITY Name/ Adresse des Herstellers: Schaller Messtechnik GmbH Max-Schaller-Straße 99 Name/ address of manufacturer: A – 8181 St. Ruprecht Produktbezeichnung: Schaller Product designation: Typenbezeichnung: PMSA Type designation: Produktbeschreibung: Messgerät zur Bestimmung des Wassergehalts in Papier...
  • Page 26 PMSA Operating Manual Für das angeführte Produkt ist eine vollständige Dokumentation mit Betriebsanleitung in Originalfassung vorhanden. For the mentioned product a complete documentation with manual of instruction in original version is available. Bei Änderungen, die nicht vom Hersteller spezifiziert sind, verliert diese Konformitätserklärung die Gültigkeit.
  • Page 27 _______________ DECLARATION OF CONFORMITY Schaller Messtechnik GmbH Name/ address of manufacturer: Max-Schaller-Straße 99 A – 8181 St. Ruprecht Product designation: Schaller PMSA Type designation: Product description: Measuring instrument for determining the water content in paper The designated product is in conformity with the following directives: Electromagnetic Compatibility Regulations 2016 Great Britain •...
  • Page 28 PMSA Operating Manual For the mentioned product, a complete documentation with manual of instruction in original version is available. In case of any changes not agreed upon with the manufacturer, this declaration of conformity loses its validity. St. Ruprecht a.d. Raab, 31.07.2022 …............
  • Page 29: Technical Data

    12.2 Technical data Measuring range 1 % to 20 % moisture content (product type dependant) Resolution of the measure- 0.01 % moisture content ment 0.1 °C / 0.3 °F temperature Operating temperature +10 °C to +40 °C Storage temperature -20 °C to +60 °C Temperature compensation automatic Paper sheet size...
  • Page 30: Notes

    PMSA Operating Manual 13. Notes Page 30...
  • Page 31 Page 31...
  • Page 32 Schaller Messtechnik develops, produces and sells professional moisture meters and turnkey solutions. Schaller Messtechnik GmbH Max-Schaller-Straße 99, A - 8181 St. Ruprecht an der Raab Tel +43 (0)3178 - 28899 , Fax +43 (0)3178 - 28899 - 901 info@humimeter.com, www.humimeter.com...

Table of Contents