PROGRAMMING
BUFFER VPD SETTING
The buffer figure will create a trigger-off point
below your set trigger point to prevent your
device from shutting off too quickly. Press
the up or down button to cycle through buffer
range from 0.1 kPa and 1.0 kPa.
BUFF.
In high VPD triggers, your device will turn on,
only turning off when the VPD falls below your
buffer setting.
In low VPD triggers, your device will turn on,
only turning off when the VPD rises above your
set buffer setting.
2.51
kPa
EXAMPLE
In this example, your High VPD Trigger is set
at 2.51 kPa and your VPD Buffer is set at 0.2
2.31
kPa
kPa. Your device will trigger on when it meets
or rises above 2.51 kPa, and only trigger off
when it falls below 2.31 kPa%. The 2.51 kPa
figure is obtained by taking your High VPD
Trigger of 2.51% and subtracting your VPD
Buffer of 0.2 kPa.
40

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CONTROLLER 69 PRO and is the answer not in the manual?

Questions and answers

Phillip Thomas
January 23, 2025

Why the low and high limits not corresponding with settings?

1 comments:
Mr. Anderson
May 14, 2025

The low and high limits on the AC Infinity CONTROLLER 69 PRO may not correspond with the settings because the device includes a bit of "wiggle room" to prevent constant triggering when values hover around the set threshold. This allows the controller to avoid repeatedly turning devices on and off when readings stay near the limit.

This answer is automatically generated

Table of Contents

Save PDF