Aqua Lung SEA LW User Manual page 10

Survival egress air
Table of Contents

Advertisement

10
NOTE: SEA does not include a HP fill adapter. The 232 bar fill adapter is available
to be purchased separately (Fig. 5).
CAUTION:
fill port and cylinder pressure rating.
CAUTION:
station unless you have received the necessary training and authorization to
do so. If done incorrectly, this procedure poses certain hazards which may
cause severe injury or death.
CAUTION:
indicate accurate cylinder filling pressure.
WARNING:
a compressor or air supply where the regulated pressure exceeds the
cylinders maximum fill pressure. Doing so could cause a dangerous
malfunction to the fill adapter, resulting in serious injury or death.
6. Inspect the fill adapter to ensure that the o-ring is
present, not damaged and seated evenly at the base
of the threads. Check the threads of the male fitting,
making sure they are clean and not damaged.
7. Insert the threaded male fitting of the fill
adapter into the fill port on the first stage. Screw
the adapter into the fill port until finger-tight. DO
NOT apply a wrench or otherwise overtighten
the fill adapter (Fig. 6).
AP0649
232 bar Fill Adapter
Ensure that the pressure rating on the HP fill adapter matches the
Do not attempt to fill SEA directly from a compressed air filling
The dial indicator is for reference only. Use the fill system gauge to
DO NOT attempt to use the HP fill adapter to fill SEA from
O-Ring
Figure 5
Fill
Adapter
Figure 6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eb001002Eb001003Eb001000Eb001001

Table of Contents