SOLAR POWER SUPPLY MODELS BPSS-10 AND BPSS-20
INSTALLATION AND OPERATING INSTRUCTIONS
1.

INTRODUCTION

The Solar Power Supply models BPSS-10 and BPSS-20 combine Securitron's renowned power
supply technology with solar capability for access control in remote/isolated locations. The BPSS
controller, contained in a NEMA-3R rated cabinet, is specifically designed for outdoor applications
and is provided with its own separately mounted, adjustable solar PV array power panel and
battery backup.
Each unit operates at 12 VDC and is intended to operate an access control
device (e.g. DK-26 keypad or card access system) and fail secure intermittent lock (e.g. GL-1
gate lock or electric strike).
requirements and functional options required to successfully install a BPSS unit.
2.

SPECIFICATIONS

Power Supply Cabinet
MODEL BPSS-10/BPSS-20 Power Supply Specifications
Cabinet Weight (without batteries)
*Maximum Output Current – Continuous
*Maximum Output Current – While Operating Lock
*Number of daily lock operations may vary due to solar activity and system current draw.
3.

RECOMMENDED TOOLS

 Hammer
 Center Punch
 Power Drill
 Drill bits
4.
It is recommended that a site survey be performed to determine the mounting location prior to
installation. The following should be considered:
The unit should be placed in a position without obstruction of the sun which will allow
optimum use of the PV array panel.
Physical strength of mounting areas should provide adequate support of the installed unit.
Adequate space should be provided for ventilation.
unobstructed space provided around the four sides of the enclosure.
Ensure wiring can be routed to protect from damage due to intrusion or vandalism. (The
enclosure is provided with knock-outs for conduit connections).
© Copyright, 2011, all rights reserved
Securitron Magnalock Corp.
Tel 800.624.5625
This manual is intended to provide the installation, electrical
Use/Environment
Cabinet Dimensions: Length
Operating Temperature Range
(with batteries)
 Wrenches
 Pliers, vise grip
 Screwdrivers: Phillips & 1/8"
Flat Blade
www.securitron.com
techsupport@securitron.com
10 Watt
PV Array Panel
Height
Depth
Voltage
Ensure that there is at least 2" of
Page 1
ASSA ABLOY, the global leader
in door opening solutions
20 Watt
PV Array Panel
Outdoor (NEMA-3R)
14 Lbs [6.4 kg]
12.8" [325mm]
12.2" [310mm]
4.7" [119mm]
11.5-14.1 Volts DC
*Up to 125mA
*Up to 425mA
-4° to +113° F
[-20° to +45° C]
 Fish Tape or Lead Wire
 Wire Strippers/Cutter
 Multimeter
PN# 500-22125
Rev. D, 08/11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SECURITRON BPSS-10 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Assa Abloy SECURITRON BPSS-10

  • Page 1 Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions SOLAR POWER SUPPLY MODELS BPSS-10 AND BPSS-20 INSTALLATION AND OPERATING INSTRUCTIONS INTRODUCTION The Solar Power Supply models BPSS-10 and BPSS-20 combine Securitron’s renowned power supply technology with solar capability for access control in remote/isolated locations.
  • Page 2 Physical Installation The BPSS controller is rated for outdoor use and is specifically designed to be affixed to a pole or post up to 2” O.D. (outer diameter) using the included hardware. Use short U-bolt in lower mounting holes to allow room for battery. A bracket kit accessory package for larger diameters is also available (see Section 6).
  • Page 3 Notes:  The controller is shipped with a jumper installed. This sets the controller for charging SEALED batteries. If a FLOODED battery is being used, simply remove the jumper to optimize the battery charging for a flooded battery. If the jumper is connected again, the charging will return to the set-points for a sealed battery.
  • Page 4 PV ARRAY PANEL INSTALLATION INSTALLING THE PANEL The following exploded illustration Figure 2 shows the included hardware required to properly mount the array panel to a vertical pole. (10 Watt PV array panel shown). 1/4-20 U-BOLT 6X #10 PLAIN FLAT WASHER 6X 10-32 X 7/16 LONG PPH SCREW 2X #10 SPLIT...
  • Page 5 ADJUSTING THE PANEL Figure 4 shows the PV array panel mounted to a vertical pole. PV ARRAY PANEL TILT ANGLE SWIVEL BRACKET PIVOT POINT 0° INCREMENTAL TRUE SOUTH ANGLE ADJUSTMENT INDICATOR SCREW 90° Figure 4 5.2.1 DIRECTION The panel can be adjusted axially to the pole by loosening the U-bolt and rotating the cross member to face the desired true South direction.
  • Page 6 SPECIALIZED MOUNTING BRACKETS  PMK-3: 3” Pole/Post Mount Kit – This bracket kit is designed for mounting a Solar Power Supply (BPSS) directly to a fence post or pole up to 3” [76mm] O.D. This kit is available through Securitron or their authorized distributors. MAINTENANCE Cleaning Methods ...
  • Page 7 Troubleshooting (Solar Controller) Problem Battery is not charging… a. Check the green LED indicator. The green “CHARGING” LED should be on if it is daytime. b. Check that the proper battery type (sealed or flooded) has been selected. c. Check that all wire connections in the system are correct and tight. Check the polarity (+ and –) of the connections.