The SGEN Generator Control
Manual part no: DOC063992 iss 2A1
Contact
on + 44 1799 531 999
dCS
(inside the UK replace + 44 with 0)
If this is the AGEN 1 generator, a Tone Generator section is displayed. Pressing
the Setup button allows you to configure the signal generator, by displaying the
following dialog:
The Clock Phase slider represents the phase offset of the generator, relative to
a zero point. You can specify the offset in AES Unit Intervals (UIs), where +128
is a one sample delay. The unit always deals in UIs, so if you change the
frequency of the output, the offset will scale accordingly to the new output
frequency.
Pressing the OK or Apply buttons will transmit the changes to the unit, which
will then act on them. The OK button closes the dialog, whilst the Apply button
leaves the dialog open (useful for tweaking the phase, for example ).
Cancel will close the dialog, discarding any changes you have made.
In addition to the four AGEN generators for the AES3 outputs, the unit also
supports six separate SGEN clock generators for the SDIF Wordclock Outputs.
Each SGEN generator is connected to two SDIF word clock outputs, and the
linkage cannot be changed. The SGEN generators are specific to their outputs,
which means that they are set up from the "Masterclock outputs" dialog. Select
the generator you wish to modify, by clicking on it (example below shows
selecting SGEN 1):
This will then display the following dialog:
Manual for Software Version 2.0x
Page 28
January 2001
file 063992ma2a1.pdf available from website