Dcs Fax Number; Panel Lock - DCS 992 User Manual

Master clock
Table of Contents

Advertisement

dCS 992 User Manual
dCS Ltd
Facs

– dCS Fax Number

Part
– Internal Number
S-No
– Serial Number
RS232
– RS-232 ID
IMPORTANT!
A-SL
– Autoslave ON/Off
Loc
– Panel Lockout
Rsout
– RS-232 Calibration data Output
AES G
– AGEN Generator Setup
Manual part no: DOC063992 iss 2A1
Contact
on + 44 1799 531 999
dCS
(inside the UK replace + 44 with 0)
dCS fax number scrolls across the display.
The control board part number (version) scrolls along the display. Although this
is recorded at dCS with the serial number, it is a good double check to give us
both these numbers when calling for help.
The control board serial number scrolls along the display. You will need
something to write this on, if you call us for help.
Displays - and allows access to – the unit's RS-232 identity code (an address
0
and 99). The address is used by the Remote Control software, to
between
send specific messages to specific units. Use menu
this address if you are controlling several units at once.
Each unit connected to a Remote Control daisy-chain MUST have a different
RS-232 address.
On
or Off. When set to On, connecting a Word Clock or GPS
Turns Auto-Slave
10MHz source to the
External Sync
LED. When set to Off, the unit ignores connection to the
Slave
input.
Panel Lock, normally Off. Set to
buttons. The menu has to be accessed to turn the lock off again.
This feature is intended for use by dCS only. It should be set to Off, especially if
you are using the Remote Control or upgrading your software.
When set to On, calibration data is sent to a PC via the
and this will slow down the Remote Control, and possibly crash your PC. Leave
it turned off!
This entry allows the phase and sample rate of the AGEN generators (1-4) to be
set up, in the absence of a PC. It is an emergency only control method – we very
strongly recommend the use of the Remote software running on a PC, and
communicating over the RS-232 link. However, if you are caught short, and
need to do it manually,
Once in the menu, at the
press of the menu
Step
press of the menu
Set
x
x
x
x
x
input causes the unit to slave and lights the
x
On
to prevent unauthorised changes using
x
Figure 6
below shows the operation of the command.
AES G
entry, vertical black arrows correspond to a
button, and horizontal grey arrows correspond to a
button.
Page 22
Manual for Software Version 2.0x
January 2001
Up
and
Down
External Sync
Loop Out
file 063992ma2a1.pdf available from website
email to: more@dcsltd.co.uk
web site: www.dcsltd.co.uk
to change
connector