Signal:u (Type And Polarity Of The Control Signal); Va:offset (Zero Point Setting) - WEST PAM-198-P Technical Documentation Manual

Power amplifier for directional valves with feedback position control
Table of Contents

Advertisement

5.3.2 SIGNAL:U (Type and polarity of the control signal)

Command
SIGNAL:U
This command is used to define the type of output signal and its polarity.
Selectable are one solenoid or two solenoid control. Furthermore the direction of the output signal can be
switched. Using applications with one solenoid it means an inverted characteristic curve. If two solenoids are
used it effects the switching of the solenoids.
1S+: One solenoid standard
U = 0... 100% -> IA = 0... 100%
o
1S-: One solenoid inverted
U = 0... 100% -> IA = 100... 0%
o
2S+: Two solenoids standard
o
U > 0 -> Controlling IA
o
U < 0 -> Controlling IB
2S-: Two solenoids switched
o
U > 0 -> Controlling IB
o
U < 0 -> Controlling IA

5.3.3 VA:OFFSET (Zero point setting)

Command
VA:OFFSET
Using valves with one solenoid this parameter defines the basic current for the zero position.
Page 22 of 33
Parameters
x
x= 1S+|1S-|2S+|2S-
Parameters
X
x= 1... 10000
PAM-198-P
Unit
Group
-
IO_CONF
Unit
Group
0.01 %
IO_CONF
1S
05.06.2020