Typical Wiring; Input Connection (Examples) - WEST PAM-198-P Technical Documentation Manual

Power amplifier for directional valves with feedback position control
Table of Contents

Advertisement

4.4

Typical wiring

Ready
Analogue command
signal input
Analogue feedback
signal input
4.5

Input connection (examples)

Joystick
8V PIN 12
+In PIN 9
-In PIN 10
GND PIN 11
SPS / PLC / SENSOR 0... 10 V
+In PIN 9 + 14
-In PIN 10 + 13
GND PIN 11
Page 15 of 33
1
5
9
Shield
+
-
0V
13
-
+
0V
4... 20 mA input
Potentiometer / Joystick
2
3
4
6
7
8
10
11
12
0V
14
15
16
3 wire connections e.g. for HAWE valves
+In PIN 9 / 14
3
-In PIN 10 / 13
4
2
1
8V PIN 12
+In PIN 9
-In PIN 10
GND PIN 11
PAM-198-P
Solenoid B
Solenoid A
12 V / 24 V
0V
Power Supply
Reference voltage output
Enable
Solenoid-A
Solenoid-B
05.06.2020