Press <config>.
Configuration window appear, you can choose special time range to show
check result.
The data can be exported through usb port.
Insert flash disk.
Press <Export>.
Export weighing data to flash disk. The data can be viewed and manipulated
in computer through Excel.
The weighing data information can be deleted
Prerequisites:
- The device has been Logon with technician account.
Press <Delete>.
Delete all the weighing data.

Setup

Product management

Prerequisite:
-
Logon with the technician account.
Press <Setup> in main interface.
Enter setup interface, as shown in Fig 6-11. In this interface, the load cell
voltage is used to check whether the load cell is in good condition. If the voltage don't
change with the load on the weighing platform or the voltage varies in wide range
(over 0.002) in static state (no obvious vibration or wind), the load cell may be
damaged (make sure there is no limit on the weighing platform).