Physical Specifications; Power And Environmental Specifications - HPE D3000 Installation Manual

Table of Contents

Advertisement

Item
5

Physical specifications

Height/Width/
Depth
Weight

Power and environmental specifications

Temperature range:
Temperature ratings
shown are for sea level.
An altitude rating of 1°C
per 300 m (1.8°F per
1,000 ft) to 3048 m
(10,000 ft) is applicable.
The upper limit might be
limited by the type and
number of options
installed.
Relative humidity:
Nonoperating maximum
humidity of 95% is based
on a temperature of 45°
C (113° F). Altitude
maximum for storage
corresponds to a
pressure minimum of 70
KPa.
Description
Health/status LED
HPE D3600/D3610 LFF: 3.44 x Height/Width/Depth 17.64 x 23.54 in (8.7 x 44.8 x 59.8 cm)
HPE D3700/D3710 SFF: 3.44 x 17.64 x 21.48 in (8.7 x 44.8 x 54.6 cm)
No disk drives: 38 lb (17.2 kg)
D3700/D3710 SFF fully populated with SFF disk drives: 54.90 lb (24.9 kg)
D3600/D3610 fully populated with LFF disk drives: 60 lb (27.2 kg)
Operating
50° to 104° F (10° to 40° C) at sea level
Shipping
-22° to 149° F (-30° to 65° C)
NOTE: Rated 1°C per 1000 feet of elevation to 10,000 ft.
Operating
10% to 90% relative humidity (Rh)
Nonoperating
0% to 95% relative humidity (Rh)
Status
Off
Solid green and amber off
Green off and solid amber
Green off and flashing
amber
Green off and amber off
State
Locate off
Normal operation
Fault
Warning
No power
Table Continued
37
Reference

Advertisement

Table of Contents
loading

This manual is also suitable for:

D3600D3610D3700D3710