GREISINGER GTF 103-Ex Series Operating Manual

GREISINGER GTF 103-Ex Series Operating Manual

Temperature probes for potentially explosive atmospheres
Hide thumbs Also See for GTF 103-Ex Series:

Advertisement

Quick Links

Z31.0.XX.6C-14
Temperature probes for
potentially explosive atmospheres
GTF 103-Ex ...
Operating Manual
0158
GHM Messtechnik GmbH • Standort Greisinger
Hans-Sachs-Str. 26 • D-93128 Regenstauf
+49 (0) 9402 / 9383-0
+49 (0) 9402 / 9383-33
info@greisinger.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GTF 103-Ex Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GREISINGER GTF 103-Ex Series

  • Page 1 Z31.0.XX.6C-14 Temperature probes for potentially explosive atmospheres GTF 103-Ex … Operating Manual 0158 GHM Messtechnik GmbH • Standort Greisinger Hans-Sachs-Str. 26 • D-93128 Regenstauf    +49 (0) 9402 / 9383-0 +49 (0) 9402 / 9383-33 info@greisinger.de...
  • Page 2: Table Of Contents

    Ordering code for GTF 103-Ex-... probes ..............16 EU - DECLARATION OF CONFORMITY ................17 10 EU - TYPE EXAMINATION CERTIFICATE ............... 18 _________________________________________________________________________________________________________________ GHM Messtechnik GmbH Hans-Sachs-Straße 26 Tel.: 09402 / 9383-0 http://www.greisinger.de Standort Greisinger D-93128 Regenstauf Fax: 09402 / 9383-33 eMail: info@greisinger.de...
  • Page 3: General Note

    Note! This symbol point out processes which can indirectly influence operation or provoke unforeseen reactions at non-observance. _________________________________________________________________________________________________________________ GHM Messtechnik GmbH Hans-Sachs-Straße 26 Tel.: 09402 / 9383-0 http://www.greisinger.de Standort Greisinger D-93128 Regenstauf Fax: 09402 / 9383-33 eMail: info@greisinger.de...
  • Page 4: Skilled Personnel

    The sum of the media temperature and the temperature from self-heating of the probe tube must always be less that the ignition temperature of the me- dium. _________________________________________________________________________________________________________________ GHM Messtechnik GmbH Hans-Sachs-Straße 26 Tel.: 09402 / 9383-0 http://www.greisinger.de Standort Greisinger D-93128 Regenstauf Fax: 09402 / 9383-33 eMail: info@greisinger.de...
  • Page 5: Additional Safety Instructions For Zone 0 Or Zone 20

    With temperatures above 100°C, all GTF 103-Ex must be ordered with a minimum extension tube length (standard = 50 mm). The extension tube length must be selected such that the _________________________________________________________________________________________________________________ GHM Messtechnik GmbH Hans-Sachs-Straße 26 Tel.: 09402 / 9383-0 http://www.greisinger.de Standort Greisinger D-93128 Regenstauf Fax: 09402 / 9383-33 eMail: info@greisinger.de...
  • Page 6: Identification

    Measuring temperatures above 400 °C => extension tube length 200 mm or longer The measuring inserts of the GTF 103-Ex series are interchangeable, except for the measur- ing inserts with a probe tube diameter of 3 mm. There a multitude of base types of GTF 103-Ex available that can all be custom assembled.
  • Page 7: Which Temperature Probe, Transmitter Do I Need

    1, 2, 21 or 22 zone 1, 2, 21 or 22 zone 0 or 20 zone 0 or 20 _________________________________________________________________________________________________________________ GHM Messtechnik GmbH Hans-Sachs-Straße 26 Tel.: 09402 / 9383-0 http://www.greisinger.de Standort Greisinger D-93128 Regenstauf Fax: 09402 / 9383-33 eMail: info@greisinger.de...
  • Page 8: Probe Types

    The GTF 103-Ex is available in wide range of versions. All variants of the GTF 103-Ex series have a large connecting head with adequate room for a head transmitter. In addition, the measuring inserts in this type series are interchangeable without removing the entire probe (except for probe tube D = 3 mm).
  • Page 9: Notes

    1500 The requirements specified in the safety instructions apply for the supply and evaluating de- vices that are used. _________________________________________________________________________________________________________________ GHM Messtechnik GmbH Hans-Sachs-Straße 26 Tel.: 09402 / 9383-0 http://www.greisinger.de Standort Greisinger D-93128 Regenstauf Fax: 09402 / 9383-33 eMail: info@greisinger.de...
  • Page 10: Installation Instructions

    The screw must be tightened firmly to ensure the IP protection rating (2.50 Nm). Over-tightening can also impair the protection rating. _________________________________________________________________________________________________________________ GHM Messtechnik GmbH Hans-Sachs-Straße 26 Tel.: 09402 / 9383-0 http://www.greisinger.de Standort Greisinger D-93128 Regenstauf Fax: 09402 / 9383-33 eMail: info@greisinger.de...
  • Page 11: Pressure Screw

    Ø 12.5 mm Clamping area 4.0 - 6.0 mm 6.5 - 8.5 mm 9 - 11 mm 11 - 12.5 mm _________________________________________________________________________________________________________________ GHM Messtechnik GmbH Hans-Sachs-Straße 26 Tel.: 09402 / 9383-0 http://www.greisinger.de Standort Greisinger D-93128 Regenstauf Fax: 09402 / 9383-33 eMail: info@greisinger.de...
  • Page 12: Specification

    Environmental temperature (max): -20 +80 °C, Maximum space for transmitter: ØxH = 44 x 21 mm or 4-pin connection base with insulating washer _________________________________________________________________________________________________________________ GHM Messtechnik GmbH Hans-Sachs-Straße 26 Tel.: 09402 / 9383-0 http://www.greisinger.de Standort Greisinger D-93128 Regenstauf Fax: 09402 / 9383-33 eMail: info@greisinger.de...
  • Page 13 “, ½“, ¾“, 10x1, 12x1.5, 14x1.5, 16x1.5, 18x1.5 Thread size: Sensor elements: Pt 100, Pt 1000, thermocouple type K _________________________________________________________________________________________________________________ GHM Messtechnik GmbH Hans-Sachs-Straße 26 Tel.: 09402 / 9383-0 http://www.greisinger.de Standort Greisinger D-93128 Regenstauf Fax: 09402 / 9383-33 eMail: info@greisinger.de...
  • Page 14: Dimensions

    Version with thread, without extension tube (connecting head = 2K) a.) Version with thread and extension tube (connecting head = 1K) _________________________________________________________________________________________________________________ GHM Messtechnik GmbH Hans-Sachs-Straße 26 Tel.: 09402 / 9383-0 http://www.greisinger.de Standort Greisinger D-93128 Regenstauf Fax: 09402 / 9383-33 eMail: info@greisinger.de...
  • Page 15: Decommissioning, Reshipment And Disposal

    Send the device directly to us (sufficiently stamped), if it should be disposed. We will dispose the device appropriate and environmentally sound. _________________________________________________________________________________________________________________ GHM Messtechnik GmbH Hans-Sachs-Straße 26 Tel.: 09402 / 9383-0 http://www.greisinger.de Standort Greisinger D-93128 Regenstauf Fax: 09402 / 9383-33 eMail: info@greisinger.de...
  • Page 16: Ordering Information

    Z31.0.XX.6C-14 Operating Manual GTF 103-Ex... page 16 of 20 8 Ordering information 8.1 Ordering code for GTF 103-Ex-... probes _________________________________________________________________________________________________________________ GHM Messtechnik GmbH Hans-Sachs-Straße 26 Tel.: 09402 / 9383-0 http://www.greisinger.de Standort Greisinger D-93128 Regenstauf Fax: 09402 / 9383-33 eMail: info@greisinger.de...
  • Page 17: Eu - Declaration Of Conformity

    Z31.0.XX.6C-14 Operating Manual GTF 103-Ex... page 17 of 20 9 EU - Declaration of conformity _________________________________________________________________________________________________________________ GHM Messtechnik GmbH Hans-Sachs-Straße 26 Tel.: 09402 / 9383-0 http://www.greisinger.de Standort Greisinger D-93128 Regenstauf Fax: 09402 / 9383-33 eMail: info@greisinger.de...
  • Page 18: Eu - Type Examination Certificate

    Z31.0.XX.6C-14 Operating Manual GTF 103-Ex... page 18 of 20 10 EU - Type Examination Certificate _________________________________________________________________________________________________________________ GHM Messtechnik GmbH Hans-Sachs-Straße 26 Tel.: 09402 / 9383-0 http://www.greisinger.de Standort Greisinger D-93128 Regenstauf Fax: 09402 / 9383-33 eMail: info@greisinger.de...
  • Page 19 Z31.0.XX.6C-14 Operating Manual GTF 103-Ex... page 19 of 20 _________________________________________________________________________________________________________________ GHM Messtechnik GmbH Hans-Sachs-Straße 26 Tel.: 09402 / 9383-0 http://www.greisinger.de Standort Greisinger D-93128 Regenstauf Fax: 09402 / 9383-33 eMail: info@greisinger.de...
  • Page 20 Z31.0.XX.6C-14 Operating Manual GTF 103-Ex... page 20 of 20 _________________________________________________________________________________________________________________ GHM Messtechnik GmbH Hans-Sachs-Straße 26 Tel.: 09402 / 9383-0 http://www.greisinger.de Standort Greisinger D-93128 Regenstauf Fax: 09402 / 9383-33 eMail: info@greisinger.de...

Table of Contents