Please read these operating instructions before unpacking and putting the unit into operation. Follow the instructions precisely as described herein. The instruction manuals on our website www.kobold.com are always for currently manufactured version of our products. Due to technical changes, the instruction manuals available online may not always correspond to the product version you have purchased.
DAG-A44 3. Instrument Inspection Instruments are inspected before shipping and sent out in perfect condition. Should damage to a device be visible, we recommend a thorough inspection of the delivery packaging. In case of damage, please inform your parcel service / forwarding agent immediately, since they are responsible for damages during transit.
DAG-A44 5. Assembly Please read the safety advice on page 13 before installation and keep this user manual for future reference. 1. After removing the fixing elements, insert the device. 2. Check the seal to make sure it fits securely. 3.
DAG-A44 6. Electrical connection with power supply 24 VDC DAG-A440 with power supply 230 VAC DAG-A444 with power supply 115 VAC DAG-A442 with power supply 24 VAC Power Supply 230 VAC or 115 VAC or 24 VAC Advice: The galvanic insulation in devices with temperature sensors, that do not have a galvanic connection to an extrinsic potential, can be cancelled by a bridge from terminal 2 to 4 and thus stabilise the device against external failures.
DAG-A44 7. Function and operation description Operation The operation is divided into two different levels. Menu Level Here it is possible to navigate between the individual menu items. Parameterization Level The parameters stored in the menu item can be parameterized here. Functions that can be adjusted or changed are always indicated with a flashing of the display.
DAG-A44 8. Setting up the device 8.1 Switching on Once the installation is complete, you can start the device by applying the current loop. Check beforehand once again that all the electrical connections are correct. Starting sequence For 1 second during the switch-on progress, the segment test (8 8 8 8) is displayed, followed by an indication of the software type and, after that, also for 1 second, the software version.
DAG-A44 8.3 Extended parameterization By pressing the [ ] & [ ] buttons during standard parameterization for one second, the display switches to the extended parameterization mode. Operation is the same as in standard parameterization. page 10 DAG-A44 K05/0123...
DAG-A44 9. Functional principle of the set points Limit value exceedance „High“ By limit value exceedance the Alarm S1-S2 is off below the threshold and on on reaching the Threshold. Limit value undercut “Low” By limit value undercut the alarm S1-S2 is on below the threshold and switched off on reaching the threshold.
DAG-A44 10. Factory settings 10.1 Default values Parameter Menu items Default 10.2 Reset to default values To return the unit to a defined basic state, a reset can be carried out to the default values. The following procedure should be used: ...
DAG-A44 11. Technical Information Operating instructions, data sheet, approvals and further information via the QR code on the device or via www.kobold.com 12. Order Codes Operating instructions, data sheet, approvals and further information via the QR code on the device or via www.kobold.com...
DAG-A44 13. Safety advice Please read the following safety advice and the assembly chapter 5 before installation and keep it for future reference Proper use The DAG-A…device is designed for the evaluation and display of sensor signals. Danger! Careless use or improper operation can result in Personal injury and / or damage to the equipment.
DAG-A44 15. Disposal Note! Avoid environmental damage caused by media-contaminated parts Dispose of the device and packaging in an environmentally friendly manner Comply with applicable national and international disposal regulations and environmental regulations. Batteries Batteries containing pollutants are marked with a sign consisting of a crossed-out garbage can and the chemical symbol (Cd, Hg, Li or Pb) of the heavy metal that is decisive for the classification as containing pollutants: 1.
DAG-A44 16. EU Declaration of Conformance We, KOBOLD Messring GmbH, Hofheim-Ts, Germany, declare under our sole responsibility that the product: Digital Indicating Unit Model: DAG-A44 to which this declaration relates is in conformity with the standards noted below: to which this declaration relates is in conformity with the standards noted below:...