Setting The Time And Day; Humidity Setpoints (4235 Only) - Braeburn 4030 User Manual

Up to 2 heat / 1 cool heat pump 1 heat / 1 cool conventional up to 3 heat / 2 cool heat pump up to 2 heat / 2 cool conventional with humidity control
Hide thumbs Also See for 4030:
Table of Contents

Advertisement

No. User Setting
4
Current Time of Day
(Hour)
Set the current hour of the day. If thermostat was configured for a 24-hour clock, the settings 0-24 will be available.
5
Current Time of Day
(Minute)
Set the current minute of the hour.
6
Current Day of Week
Set the current day of the week.
Humidification Setpoint HUMID SET 10 RH%
7
[Only available if humidification was enabled] Select a humidification setpoint. When the relative humidity (RH%) falls
below this setpoint, the thermostat will activate your humidification equipment. During a call for humidification, the
thermostat will display HUMIDIFY in the lower left corner of the display.
8
Dehumidification
Setpoint
[Only available if dehumidification was enabled] Select a dehumidification setpoint. When the relative humidity (RH%)
rises above this setpoint, the thermostat will activate your dehumidification equipment. During a call for dehumidification,
the thermostat will display DEHUMIDIFY in the lower left corner of the display. Your thermostat can also be configured to
use the air conditioning system to reduce humidity during the cooling season by running an additional 1-3 degrees below
your cooling setpoint temperature if needed to reduce humidity.
User Manual
Displayed Default
Setting
SET TIME
12:00
SET TIME
12:00
SET DAY
MON
DEHUMID 80 RH%
SET
10
Available Description of
Settings
Available Settings
1-12
Select the current hour of day
00-60 Select the current minute of the hour
MON-SUN Select the current day of the week
10% - 50% Select the humidification setpoint
80%-40% Select the dehumidification setpoint